Monoenergetic photon pencil beam

From UCL HEP PBT Wiki

Jump to: navigation, search
m
Line 267: Line 267:
'''Change the incident particle energy'''
'''Change the incident particle energy'''
-
The default energy is 20 MeV. It is a typical energy used in radiotherapy. In gamma.mac you can change the value of 20 MeV  
+
The default energy is 20 MeV. The typical therapeutic beam energy used in radiotherapy is in the interval 0.3 to 20 MeV. In gamma.mac you can change the value of 20 MeV  
<pre style="color: #800000; background-color: #dcdcdc">
<pre style="color: #800000; background-color: #dcdcdc">
Line 273: Line 273:
</pre>
</pre>
-
to, for example, 10 MeV
+
to, for example, 1.25 MeV
<pre style="color: #800000; background-color: #dcdcdc">
<pre style="color: #800000; background-color: #dcdcdc">
-
/gun/energy 10 MeV
+
/gun/energy 1.25 MeV
</pre>
</pre>
 +
This is the energy of the photon beams from cobalt-60 therapy machines.
Keep in mind that the primary particle generation is done at /PhotonPB_source/src/PrimaryGeneratorAction.cc.
Keep in mind that the primary particle generation is done at /PhotonPB_source/src/PrimaryGeneratorAction.cc.

Revision as of 14:25, 24 August 2014

Personal tools