| style="text-align: center;" | Single Module Scintillator Block  | | style="text-align: center;" | Single Module Scintillator Block  | ||
| style="text-align: center;" | Optical gel required to couple Scintillator to PMT  | | style="text-align: center;" | 3cm x 3cm x 5cm standard scintillator block. Optical gel required to couple Scintillator to PMT  | ||
|-  | |-  | ||
| style="text-align: center;" | Photomultiplier Tube  | | style="text-align: center;" | Photomultiplier Tube  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Hamamatsu R13089 2"    | ||
|-  | |-  | ||
| style="text-align: center;" | Portable Enclosure  | | style="text-align: center;" | Portable Enclosure  | ||
| Line 17: | Line 17: | ||
230 x 555 x 350mm <br/>  | 230 x 555 x 350mm <br/>  | ||
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/>  | Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/>  | ||
Mylar window with Al support mounted to internal face: approximately light-tight.  | Mylar window with Al support mounted to internal face: approximately light-tight. <br/>  | ||
BNC output from case connected to SMA splitter.  | |||
|-  | |-  | ||
| style="text-align: center;" | LeCroy HDO6104 Oscilloscope  | | style="text-align: center;" | LeCroy HDO6104 Oscilloscope  | ||
| style="text-align: center;" | Records PMT output  | | style="text-align: center;" | Records PMT output, connected via SMA-BNC conversion.  | ||
|-  | |||
| style="text-align: center;" | Caen DT5751 Digitiser  | |||
| style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3.  | |||
|-  | |-  | ||
| style="text-align: center;" | DAQ Laptop  | | style="text-align: center;" | DAQ Laptop  | ||
| Line 28: | Line 32: | ||
| style="text-align: center;" | Supplies HV to PMT  | | style="text-align: center;" | Supplies HV to PMT  | ||
|-  | |-  | ||
| style="text-align: center;" | Control Laptop x   | | style="text-align: center;" | PRaVDA Strip Tracker  | ||
| style="text-align: center;" |   | | style="text-align: center;" | PRaVDA Unit A, 3x150um Si strip sensors with 90.4um strip pitch. <br/> Firmware version update to yield square pulse out when 2 or 3 layers have a strip over threshold per read out cycle  | ||
|-  | |||
| style="text-align: center;" | Control Laptop x 3  | |||
| style="text-align: center;" | Two used for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Third used for taking down notes.  | |||
|-  | |-  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Ethernet Switcher  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Set in experiment room and connected LeCroy Oscilloscope and DAQ laptop. Output sent to control room Network Hub.  | ||
|-  | |-  | ||
| style="text-align: center;" | Ethernet Cable x   | | style="text-align: center;" | Network Hub  | ||
| style="text-align: center;" | To connect   | | style="text-align: center;" | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi.  | ||
|-  | |||
| style="text-align: center;" | Ethernet Cable x 3  | |||
| style="text-align: center;" | To connect 1 control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs.  | |||
|-  | |-  | ||
| style="text-align: center;" | Ethernet Cable  | | style="text-align: center;" | Ethernet Cable  | ||
| style="text-align: center;" | To connect   | | style="text-align: center;" | To connect control Network Hub to Ethernet Switcher.  | ||
|-  | |-  | ||
| style="text-align: center;" | SMA   | | style="text-align: center;" | Male-to-Male SMA Cable  | ||
| style="text-align: center;" | Signal from enclosure port to   | | style="text-align: center;" | Signal from enclosure port to Splitter  | ||
|-  | |-  | ||
| style="text-align: center;" |   | | style="text-align: center;" | DC-4200 MHz Signal Splitter  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Splits SMA signal to two SMA signals – sent to Oscilloscope and Digitiser.   | ||
|-  | |||
| style="text-align: center;" | Male SMA to Male BNC cable  | |||
| style="text-align: center;" | Sends 1 output from splitter to Oscilloscope.  | |||
|-  | |||
| style="text-align: center;" | Male SMA to Male MCX cable  | |||
| style="text-align: center;" | Sends 1 output from splitter to Digitiser  | |||
|-  | |-  | ||
| style="text-align: center;" | USB Cable  | | style="text-align: center;" | USB Cable  | ||
| Line 58: | Line 73: | ||
| style="text-align: center;" | Wipes  | | style="text-align: center;" | Wipes  | ||
| style="text-align: center;" | For removing optical gel  | | style="text-align: center;" | For removing optical gel  | ||
|}  | |}  | ||
== Experiment List ==  | |||
28 MeV beam  | |||
Scattering Foil in  | |||
2mm diameter collimator  | |||
10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation  | |||
# Bragg Peak Measurements  | |||
# Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold  | |||
# Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold  | |||
# Degrade beam energy and measure response with 1-6mm PMMA before calorimeter  | |||
# PRaVDA box with 2mm collimator, trigger from scope  | |||
# PRaVDA box with 2mm collimator for trigger output  | |||
36 MeV beam  | |||
Scattering Foil in  | |||
2mm diameter collimator  | |||
10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation  | |||
# Bragg Peak Measurements  | |||
# Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold  | |||
# Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold  | |||
# Degrade beam energy and measure response with 1-6mm PMMA before calorimeter  | |||
# Offset 2mm collimator (by 6mm) for optimal trigger threshold  | |||
# Double 2mm collimator (12mm separated) for optimal trigger threshold  | |||
# PRaVDA box with 2mm collimator, trigger from scope  | |||
# PRaVDA box with 2mm collimator for trigger output  | |||
# Degrade beam with 1-6mm PMMA with tracker  | |||
==Experiment Log==  | |||
'''25/10/18'''  | |||
# Set up apparatus as described in equipment list.  | |||
# Beam experienced difficulties, delaying data collection.  | |||
# Tracker operates on a 26MHz clock, and a trigger is sent whenever 2/3 silicon layers in tracker record events in a timestamp. Trigger tests were conducted with noise, hence a random rate in tests below.  | |||
# Tested trigger output of Tracker into Oscilloscope: square wave of period ~15 ns with amplitude ~400 mV. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger  | |||
# Placed signal splitter for trigger to send to both Digitiser and Oscilloscope. Amplitude reduced to ~50%. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger (Split)  | |||
# Split trigger found to be too small for Digitiser (accepts trigger of order ~V), hence Digitiser set to self-trigger mode.   | |||
# Aligned calorimeter to tracker, with centre of mylar window and tracker window aligned approximately by eye.  | |||
# Performed beam test (had approx 30 mins beam time), details provided below.  | |||
# Was found that the tracker was not completely set centre to the beam.  | |||
# Error in data taking: Trigger trace was recorded instead of PMT trace.  | |||
'''26/10/18'''  | |||
# Tracker was realigned to be centred to the beam.  | |||
# Using Tipp-Ex markers and lable stickers, window to scintillator was aligned more accurately to window of tracker.  | |||
# Test of tracker/PMT synchronisation (check tracker trigger pulse/PMT pulse sync and numbers of events in files) with scope vertical scale 50mV/div. Window center corresponds to right edge vertical line intersecting upper edge horizontal line, looking at the window.  | |||
# Test of tracker/PMT synchronisation with scope vertical scale 100mV/div, 2mm collimator centered.  | |||
# Test of tracker/PMT synchronisation with lower current, 2mm collimator centered.  | |||
# Degrade beam energy and measure response with 0.95mm, 2.01mm, 2.96mm, 3.95mm, 4.90mm, 5.70mm PMMA before calorimeter, 2mm collimator centered.   | |||
# Offset 2mm collimator (by 6mm in +ve) and measure response with 5.70 mm PMMA absorber.  | |||
# Double 2mm collimator (12mm separated in x direction) and measure response with 5.70 mm PMMA absorber.   | |||
# Offset 2mm collimator (by 6mm in +ve), no absorber.  | |||
# Double 2mm collimator (12mm separated in x direction), no absorber.   | |||
# Double 2mm collimator (12mm separated in x direction) repetition with lower current, no absorber.   | |||
# Double 2mm collimator (12mm separated in x direction) with left-hand hole covered by 3.95 mm PMMA.  | |||
== Beam Tests ==  | == Beam Tests ==  | ||
=== Thursday 25th October ===  | |||
PMT Current at HV supply -900 V, beam off: 150 μA  | PMT Current at HV supply -900 V, beam off: 150 μA  | ||
28MeV beam. Scope triggered by tracker.  Cyclotron issues meant short run (~90 mins).  Test of tracker triggering/scope synchronisation.  | |||
Scope timebase: 20ns/div; trigger delay 80ns; C1 vertical scale 50mV/div.    | |||
Tracker data indicates beam horizontal offset of 12mm; vertical offset of 1.3mm.  | |||
Data stored in directory ProCal_Birm_25-10-18  | |||
{| class="wikitable"  | |||
! style="text-align: center;" | Run Number  | |||
! style="text-align: center;" | High Voltage (V)  | |||
! style="text-align: center;" | Trigger Level (mV)  | |||
! style="text-align: center;" | Trigger Source  | |||
! style="text-align: center;" | Beam Current / Rate  | |||
! style="text-align: center;" | Collimator  | |||
! style="text-align: center;" | Filename  | |||
! style="text-align: center;" | Notes  | |||
|-  | |||
| style="text-align: center;" | 00  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 170pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred  | |||
| style="text-align: center;" | run00_2mmCCol_160pA_TrackTrig  | |||
| style="text-align: center;" | First test of tracker/PMT synchronisation  | |||
|-  | |||
| style="text-align: center;" | 01  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 160pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred  | |||
| style="text-align: center;" | run01_2mmCCol_160pA_TrackTrig  | |||
| style="text-align: center;" | Also took Caen ADC data  | |||
|-  | |||
| style="text-align: center;" | 02  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 160pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred  | |||
| style="text-align: center;" | run02_2mmCCol_160pA_TrackTrig  | |||
| style="text-align: center;" | Caen ADC run 01 data also includes run 02 (long run)  | |||
|-  | |||
|}  | |||
=== Friday 26th October ===  | |||
PMT Current at HV supply -900 V (actual 899.8V), beam off: 150.15 μA.  | |||
36MeV beam: scattering foil inserted to increase beam size; 2 mm on-axis collimator.  | |||
Scope triggered by tracker.  Scope timebase: 20ns/div; trigger delay 80ns; C1 vertical scale 50mV/div.    | |||
Data stored in directory ProCal_Birm_26-10-18  | |||
{| class="wikitable"  | {| class="wikitable"  | ||
! style="text-align: center;" | Run Number  | ! style="text-align: center;" | Run Number  | ||
! style="text-align: center;" | High Voltage (V)  | ! style="text-align: center;" | High Voltage (V)  | ||
! style="text-align: center;" |   | ! style="text-align: center;" | Trigger Level (mV)  | ||
! style="text-align: center;" |   | ! style="text-align: center;" | Trigger Source  | ||
! style="text-align: center;" | Beam Current / Rate  | |||
! style="text-align: center;" | Collimator  | ! style="text-align: center;" | Collimator  | ||
! style="text-align: center;" |   | ! style="text-align: center;" | Filename  | ||
! style="text-align: center;" | Notes  | ! style="text-align: center;" | Notes  | ||
|-  | |-  | ||
| style="text-align: center;" | 00  | | style="text-align: center;" | 00  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 160-200pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run00_2mmCCol_160pA_TrackTrig  | ||
|   | | Test of tracker/PMT synchronisation with 5s tracker run, 50,000 scope segments, all traces saved; check tracker trigger pulse/PMT pulse sync and numbers of events in files.  | ||
|-  | |-  | ||
| style="text-align: center;" | 01  | | style="text-align: center;" | 01  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 160-170pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run01_2mmCCol_160pA_TrackTrig  | ||
|   | | Repeat of previous test; scope vertical trace increased to 100mV/div.  | ||
|-  | |-  | ||
| style="text-align: center;" | 02  | | style="text-align: center;" | 02  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 100pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run02_2mmCCol_100pA_TrackTrig  | ||
|   | | Lower current check.  | ||
|-  | |-  | ||
| style="text-align: center;" | 03  | | style="text-align: center;" | 03  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 80pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run03_2mmCCol_80pA_TrackTrig  | ||
|   | | Repeat of run 2, no ADC data.  | ||
|-  | |-  | ||
| style="text-align: center;" | 04  | | style="text-align: center;" | 04  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 90pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 0.95mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run04_2mmCCol_90pA_1mmPMMA  | ||
|   | | Tracker triggered, 0.95mm PMMA.  | ||
|-  | |-  | ||
| style="text-align: center;" | 05  | | style="text-align: center;" | 05  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 0.95mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run05_2mmCCol_70pA_1mmPMMA  | ||
|   | | Repeat of run 4 (ADC data for runs 4, 5 and 6).  | ||
|-  | |-  | ||
| style="text-align: center;" | 06  | | style="text-align: center;" | 06  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 80pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 0.95mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run06_2mmCCol_80pA_1mmPMMA  | ||
|   | | Repeat of run 4 (ADC data for runs 4, 5 and 6).  | ||
|-  | |-  | ||
| style="text-align: center;" | 07  | | style="text-align: center;" | 07  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 60pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 2.01mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run07_2mmCCol_60pA_2mmPMMA  | ||
|   | | Tracker triggered, 2.01mm PMMA.  | ||
|-  | |-  | ||
| style="text-align: center;" | 08  | | style="text-align: center;" | 08  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 80pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 2.01mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run08_2mmCCol_80pA_2mmPMMA  | ||
| Repeat of run 7 (ADC data for runs 7, 8 and 9).  | |||
|-  | |-  | ||
| style="text-align: center;" | 09  | | style="text-align: center;" | 09  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 90pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 2.01mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run09_2mmCCol_90pA_2mmPMMA  | ||
|   | | Repeat of run 7 (ADC data for runs 7, 8 and 9).  | ||
|-  | |-  | ||
| style="text-align: center;" | 10  | | style="text-align: center;" | 10  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" |   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 80pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 2.96mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run10_2mmCCol_80pA_3mmPMMA  | ||
|   | | Tracker triggered, 2.96mm PMMA.  | ||
|-  | |-  | ||
| style="text-align: center;" | 11  | | style="text-align: center;" | 11  | ||
| style="text-align: center;" | -900  | | style="text-align: center;" | -900  | ||
| style="text-align: center;" | -  | | style="text-align: center;" | 70, +ve  | ||
| style="text-align: center;" | 10   | | style="text-align: center;" | Tracker (C2)  | ||
| style="text-align: center;" | 5 mm  | | style="text-align: center;" | 85pA/~10 kHz  | ||
| style="text-align: center;" |   | | style="text-align: center;" | 2 mm centred, 2.96mm PMMA  | ||
| style="text-align: center;" |   | | style="text-align: center;" | run11_2mmCCol_85pA_3mmPMMA  | ||
| style="text-align: center;" | 1 mm   | | Repeat of run 10 (ADC data for runs 10, 11 and 12).  | ||
|-  | |||
| style="text-align: center;" | 12  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 90pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 2.96mm PMMA  | |||
| style="text-align: center;" | run12_2mmCCol_90pA_3mmPMMA  | |||
| Repeat of run 10 (ADC data for runs 10, 11 and 12).  | |||
|-  | |||
| style="text-align: center;" | 13  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 3.95mm PMMA  | |||
| style="text-align: center;" | run13_2mmCCol_50pA_4mmPMMA  | |||
| Tracker triggered, 3.95mm PMMA.  | |||
|-  | |||
| style="text-align: center;" | 14  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 77pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 3.95mm PMMA  | |||
| style="text-align: center;" | run14_2mmCCol_77pA_4mmPMMA  | |||
| Repeat of run 13 (ADC data for runs 13, 14 and 15).  | |||
|-  | |||
| style="text-align: center;" | 15  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 90pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 3.95mm PMMA  | |||
| style="text-align: center;" | run15_2mmCCol_90pA_4mmPMMA  | |||
| Repeat of run 13 (ADC data for runs 13, 14 and 15).  | |||
|-  | |||
| style="text-align: center;" | 16  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 70pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 4.90mm PMMA  | |||
| style="text-align: center;" | run16_2mmCCol_70pA_5mmPMMA  | |||
| Tracker triggered, 4.90mm PMMA.  Large current fluctuations: check shape of ADC spectrum.  | |||
|-  | |||
| style="text-align: center;" | 17  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 65pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 4.90mm PMMA  | |||
| style="text-align: center;" | run17_2mmCCol_65pA_5mmPMMA  | |||
| Repeat of run 16 (ADC data for runs 16, 17 and 18).  | |||
|-  | |||
| style="text-align: center;" | 18  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 60pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 4.90mm PMMA  | |||
| style="text-align: center;" | run18_2mmCCol_60pA_5mmPMMA  | |||
| Repeat of run 16 (ADC data for runs 16, 17 and 18).  | |||
|-  | |||
| style="text-align: center;" | 19  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 5.70mm PMMA  | |||
| style="text-align: center;" | run19_2mmCCol_50pA_6mmPMMA  | |||
| Tracker triggered, 5.70mm PMMA.  | |||
|-  | |||
| style="text-align: center;" | 20  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 5.70mm PMMA  | |||
| style="text-align: center;" | run20_2mmCCol_50pA_6mmPMMA  | |||
| Repeat of run 19 (ADC data for runs 19, 20 and 21).  | |||
|-  | |||
| style="text-align: center;" | 21  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 60pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm centred, 5.70mm PMMA  | |||
| style="text-align: center;" | run21_2mmCCol_60pA_6mmPMMA  | |||
| Repeat of run 19 (ADC data for runs 19, 20 and 21).  | |||
|-  | |||
| style="text-align: center;" | 22  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 90-140pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset in +ve x, 5.70mm PMMA.  | |||
| style="text-align: center;" | run22_2mmOSCol_100pA_6mmPMMA  | |||
| Tracker triggered, 2 mm collimator with 6 mm offset in +ve x direction; 5.70 mm PMMA absorber.  | |||
|-  | |||
| style="text-align: center;" | 23  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 85-120pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset, 5.70mm PMMA  | |||
| style="text-align: center;" | run23_2mmOSCol_100pA_6mmPMMA  | |||
| Repeat of run 22 (ADC data for runs 22, 23 and 24).  | |||
|-  | |||
| style="text-align: center;" | 24  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 10-75pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset, 5.70mm PMMA  | |||
| style="text-align: center;" | run24_2mmOSCol_70pA_6mmPMMA  | |||
| Repeat of run 22 (ADC data for runs 22, 23 and 24).  | |||
|-  | |||
| style="text-align: center;" | 25  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 40-50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart in x, 5.70mm PMMA  | |||
| style="text-align: center;" | run25_2mmSBCol_40pA_6mmPMMA  | |||
| Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction, 5.70 mm PMMA absorber.  | |||
|-  | |||
| style="text-align: center;" | 26  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 45pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart, 5.70mm PMMA  | |||
| style="text-align: center;" | run26_2mmSBCol_45pA_6mmPMMA  | |||
| Repeat of run 25 (ADC data for runs 25, 26 and 27).  | |||
|-  | |||
| style="text-align: center;" | 27  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 45-55pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart, 5.70mm PMMA  | |||
| style="text-align: center;" | run27_2mmSBCol_50pA_6mmPMMA  | |||
| Repeat of run 25 (ADC data for runs 25, 26 and 27).  | |||
|-  | |||
| style="text-align: center;" | 28  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 70-90pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset in +ve x.  | |||
| style="text-align: center;" | run28_2mmOSCol_70pA_TrackTrig  | |||
| Tracker triggered, 2 mm collimator with 6 mm offset in +ve x direction.  | |||
|-  | |||
| style="text-align: center;" | 29  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 60pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset  | |||
| style="text-align: center;" | run29_2mmOSCol_60pA_TrackTrig  | |||
| Repeat of run 28 (ADC data for runs 28, 29 and 30).  | |||
|-  | |||
| style="text-align: center;" | 30  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 60pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm with 6mm offset  | |||
| style="text-align: center;" | run30_2mmOSCol_60pA_TrackTrig  | |||
| Repeat of run 28 (ADC data for runs 28, 29 and 30).  | |||
|-  | |||
| style="text-align: center;" | 31  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 40-50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart in x.  | |||
| style="text-align: center;" | run31_2mmSBCol_46pA_TrackTrig  | |||
| Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction.  | |||
|-  | |||
| style="text-align: center;" | 32  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 40-50pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart  | |||
| style="text-align: center;" | run32_2mmSBCol_45pA_TrackTrig  | |||
| Repeat of run 31 (ADC data for runs 31, 32 and 33).  | |||
|-  | |||
| style="text-align: center;" | 33  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 35-40pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart  | |||
| style="text-align: center;" | run33_2mmSBCol_40pA_TrackTrig  | |||
| Repeat of run 31 (ADC data for runs 31, 32 and 33); large current dropout.  | |||
|-  | |||
| style="text-align: center;" | 34  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 10pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart in x.  | |||
| style="text-align: center;" | run34_2mmSBCol_10pA_TrackTrig  | |||
| Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; lower current repeat of 2 hole collimator.  | |||
|-  | |||
| style="text-align: center;" | 35  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 10pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart  | |||
| style="text-align: center;" | run35_2mmSBCol_10pA_TrackTrig  | |||
| Repeat of run 34 (ADC data for runs 34, 35 and 36).  | |||
|-  | |||
| style="text-align: center;" | 36  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 8pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart  | |||
| style="text-align: center;" | run36_2mmSBCol_8pA_TrackTrig  | |||
| Repeat of run 34 (ADC data for runs 34, 35 and 36).  | |||
|-  | |||
| style="text-align: center;" | 37  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 20-24pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run37_2mmEPCol_20pA_4mmPMMA  | |||
| Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; left-hand hole covered by 3.95&mm PMMA.  | |||
|-  | |||
| style="text-align: center;" | 38  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 11pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run38_2mmEPCol_11pA_4mmPMMA  | |||
| Repeat of run 37 (ADC data for runs 37, 38 and 39).  | |||
|-  | |||
| style="text-align: center;" | 39  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 9pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run39_2mmEPCol_9pA_4mmPMMA  | |||
| Repeat of run 37 (ADC data for runs 37, 38 and 39).  | |||
|-  | |||
| style="text-align: center;" | 40  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 20-70pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run40_2mmEPCol_40pA_4mmPMMA  | |||
| Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; left-hand hole covered by 3.95&mm PMMA.  | |||
|-  | |||
| style="text-align: center;" | 41  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 40-120pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run41_2mmEPCol_40pA_4mmPMMA  | |||
| Repeat of run 40 (ADC data for runs 40, 41 and 42); large current fluctuations.  | |||
|-  | |||
| style="text-align: center;" | 42  | |||
| style="text-align: center;" | -900  | |||
| style="text-align: center;" | 70, +ve  | |||
| style="text-align: center;" | Tracker (C2)  | |||
| style="text-align: center;" | 15-45pA/~10 kHz  | |||
| style="text-align: center;" | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole.  | |||
| style="text-align: center;" | run42_2mmEPCol_30pA_4mmPMMA  | |||
| Repeat of run 40 (ADC data for runs 40, 41 and 42).  | |||
|-  | |||
|}  | |}  | ||
Latest revision as of 10:30, 2 November 2018
Beam tests of the single module with PRaVDA Silicon strip tracker with trigger pulse output at the Birmingham Cyclotron with a 36 MeV beam.
Equipment List
| Item | Notes | 
|---|---|
| Single Module Scintillator Block | 3cm x 3cm x 5cm standard scintillator block. Optical gel required to couple Scintillator to PMT | 
| Photomultiplier Tube | Hamamatsu R13089 2" | 
| Portable Enclosure | Modified Peli 1510 Waterproof Wheeled Equipment Case.  230 x 555 x 350mm   | 
| LeCroy HDO6104 Oscilloscope | Records PMT output, connected via SMA-BNC conversion. | 
| Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | 
| DAQ Laptop | Controls Caen HV supply; records data from Caen digitiser. | 
| Caen NDT1470 HV Supply | Supplies HV to PMT | 
| PRaVDA Strip Tracker | PRaVDA Unit A, 3x150um Si strip sensors with 90.4um strip pitch.  Firmware version update to yield square pulse out when 2 or 3 layers have a strip over threshold per read out cycle  | 
| Control Laptop x 3 | Two used for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Third used for taking down notes. | 
| Ethernet Switcher | Set in experiment room and connected LeCroy Oscilloscope and DAQ laptop. Output sent to control room Network Hub. | 
| Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. | 
| Ethernet Cable x 3 | To connect 1 control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs. | 
| Ethernet Cable | To connect control Network Hub to Ethernet Switcher. | 
| Male-to-Male SMA Cable | Signal from enclosure port to Splitter | 
| DC-4200 MHz Signal Splitter | Splits SMA signal to two SMA signals – sent to Oscilloscope and Digitiser. | 
| Male SMA to Male BNC cable | Sends 1 output from splitter to Oscilloscope. | 
| Male SMA to Male MCX cable | Sends 1 output from splitter to Digitiser | 
| USB Cable | Caen HV unit to DAQ Laptop | 
| Gloves | For handling scintillator | 
| Optical gel | For coupling scintillator to PMT | 
| Wipes | For removing optical gel | 
Experiment List
28 MeV beam Scattering Foil in 2mm diameter collimator 10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation
- Bragg Peak Measurements
 - Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold
 - Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold
 - Degrade beam energy and measure response with 1-6mm PMMA before calorimeter
 - PRaVDA box with 2mm collimator, trigger from scope
 - PRaVDA box with 2mm collimator for trigger output
 
36 MeV beam
Scattering Foil in
2mm diameter collimator
10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation
- Bragg Peak Measurements
 - Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold
 - Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold
 - Degrade beam energy and measure response with 1-6mm PMMA before calorimeter
 - Offset 2mm collimator (by 6mm) for optimal trigger threshold
 - Double 2mm collimator (12mm separated) for optimal trigger threshold
 - PRaVDA box with 2mm collimator, trigger from scope
 - PRaVDA box with 2mm collimator for trigger output
 - Degrade beam with 1-6mm PMMA with tracker
 
Experiment Log
25/10/18
- Set up apparatus as described in equipment list.
 - Beam experienced difficulties, delaying data collection.
 - Tracker operates on a 26MHz clock, and a trigger is sent whenever 2/3 silicon layers in tracker record events in a timestamp. Trigger tests were conducted with noise, hence a random rate in tests below.
 - Tested trigger output of Tracker into Oscilloscope: square wave of period ~15 ns with amplitude ~400 mV. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger
 - Placed signal splitter for trigger to send to both Digitiser and Oscilloscope. Amplitude reduced to ~50%. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger (Split)
 - Split trigger found to be too small for Digitiser (accepts trigger of order ~V), hence Digitiser set to self-trigger mode.
 - Aligned calorimeter to tracker, with centre of mylar window and tracker window aligned approximately by eye.
 - Performed beam test (had approx 30 mins beam time), details provided below.
 - Was found that the tracker was not completely set centre to the beam.
 - Error in data taking: Trigger trace was recorded instead of PMT trace.
 
26/10/18
- Tracker was realigned to be centred to the beam.
 - Using Tipp-Ex markers and lable stickers, window to scintillator was aligned more accurately to window of tracker.
 - Test of tracker/PMT synchronisation (check tracker trigger pulse/PMT pulse sync and numbers of events in files) with scope vertical scale 50mV/div. Window center corresponds to right edge vertical line intersecting upper edge horizontal line, looking at the window.
 - Test of tracker/PMT synchronisation with scope vertical scale 100mV/div, 2mm collimator centered.
 - Test of tracker/PMT synchronisation with lower current, 2mm collimator centered.
 - Degrade beam energy and measure response with 0.95mm, 2.01mm, 2.96mm, 3.95mm, 4.90mm, 5.70mm PMMA before calorimeter, 2mm collimator centered.
 - Offset 2mm collimator (by 6mm in +ve) and measure response with 5.70 mm PMMA absorber.
 - Double 2mm collimator (12mm separated in x direction) and measure response with 5.70 mm PMMA absorber.
 - Offset 2mm collimator (by 6mm in +ve), no absorber.
 - Double 2mm collimator (12mm separated in x direction), no absorber.
 - Double 2mm collimator (12mm separated in x direction) repetition with lower current, no absorber.
 - Double 2mm collimator (12mm separated in x direction) with left-hand hole covered by 3.95 mm PMMA.
 
Beam Tests
Thursday 25th October
PMT Current at HV supply -900 V, beam off: 150 μA
28MeV beam. Scope triggered by tracker. Cyclotron issues meant short run (~90 mins). Test of tracker triggering/scope synchronisation.
Scope timebase: 20ns/div; trigger delay 80ns; C1 vertical scale 50mV/div.
Tracker data indicates beam horizontal offset of 12mm; vertical offset of 1.3mm.
Data stored in directory ProCal_Birm_25-10-18
| Run Number | High Voltage (V) | Trigger Level (mV) | Trigger Source | Beam Current / Rate | Collimator | Filename | Notes | 
|---|---|---|---|---|---|---|---|
| 00 | -900 | 70, +ve | Tracker (C2) | 170pA/~10 kHz | 2 mm centred | run00_2mmCCol_160pA_TrackTrig | First test of tracker/PMT synchronisation | 
| 01 | -900 | 70, +ve | Tracker (C2) | 160pA/~10 kHz | 2 mm centred | run01_2mmCCol_160pA_TrackTrig | Also took Caen ADC data | 
| 02 | -900 | 70, +ve | Tracker (C2) | 160pA/~10 kHz | 2 mm centred | run02_2mmCCol_160pA_TrackTrig | Caen ADC run 01 data also includes run 02 (long run) | 
Friday 26th October
PMT Current at HV supply -900 V (actual 899.8V), beam off: 150.15 μA.
36MeV beam: scattering foil inserted to increase beam size; 2 mm on-axis collimator.
Scope triggered by tracker. Scope timebase: 20ns/div; trigger delay 80ns; C1 vertical scale 50mV/div.
Data stored in directory ProCal_Birm_26-10-18
| Run Number | High Voltage (V) | Trigger Level (mV) | Trigger Source | Beam Current / Rate | Collimator | Filename | Notes | 
|---|---|---|---|---|---|---|---|
| 00 | -900 | 70, +ve | Tracker (C2) | 160-200pA/~10 kHz | 2 mm centred | run00_2mmCCol_160pA_TrackTrig | Test of tracker/PMT synchronisation with 5s tracker run, 50,000 scope segments, all traces saved; check tracker trigger pulse/PMT pulse sync and numbers of events in files. | 
| 01 | -900 | 70, +ve | Tracker (C2) | 160-170pA/~10 kHz | 2 mm centred | run01_2mmCCol_160pA_TrackTrig | Repeat of previous test; scope vertical trace increased to 100mV/div. | 
| 02 | -900 | 70, +ve | Tracker (C2) | 100pA/~10 kHz | 2 mm centred | run02_2mmCCol_100pA_TrackTrig | Lower current check. | 
| 03 | -900 | 70, +ve | Tracker (C2) | 80pA/~10 kHz | 2 mm centred | run03_2mmCCol_80pA_TrackTrig | Repeat of run 2, no ADC data. | 
| 04 | -900 | 70, +ve | Tracker (C2) | 90pA/~10 kHz | 2 mm centred, 0.95mm PMMA | run04_2mmCCol_90pA_1mmPMMA | Tracker triggered, 0.95mm PMMA. | 
| 05 | -900 | 70, +ve | Tracker (C2) | 70pA/~10 kHz | 2 mm centred, 0.95mm PMMA | run05_2mmCCol_70pA_1mmPMMA | Repeat of run 4 (ADC data for runs 4, 5 and 6). | 
| 06 | -900 | 70, +ve | Tracker (C2) | 80pA/~10 kHz | 2 mm centred, 0.95mm PMMA | run06_2mmCCol_80pA_1mmPMMA | Repeat of run 4 (ADC data for runs 4, 5 and 6). | 
| 07 | -900 | 70, +ve | Tracker (C2) | 60pA/~10 kHz | 2 mm centred, 2.01mm PMMA | run07_2mmCCol_60pA_2mmPMMA | Tracker triggered, 2.01mm PMMA. | 
| 08 | -900 | 70, +ve | Tracker (C2) | 80pA/~10 kHz | 2 mm centred, 2.01mm PMMA | run08_2mmCCol_80pA_2mmPMMA | Repeat of run 7 (ADC data for runs 7, 8 and 9). | 
| 09 | -900 | 70, +ve | Tracker (C2) | 90pA/~10 kHz | 2 mm centred, 2.01mm PMMA | run09_2mmCCol_90pA_2mmPMMA | Repeat of run 7 (ADC data for runs 7, 8 and 9). | 
| 10 | -900 | 70, +ve | Tracker (C2) | 80pA/~10 kHz | 2 mm centred, 2.96mm PMMA | run10_2mmCCol_80pA_3mmPMMA | Tracker triggered, 2.96mm PMMA. | 
| 11 | -900 | 70, +ve | Tracker (C2) | 85pA/~10 kHz | 2 mm centred, 2.96mm PMMA | run11_2mmCCol_85pA_3mmPMMA | Repeat of run 10 (ADC data for runs 10, 11 and 12). | 
| 12 | -900 | 70, +ve | Tracker (C2) | 90pA/~10 kHz | 2 mm centred, 2.96mm PMMA | run12_2mmCCol_90pA_3mmPMMA | Repeat of run 10 (ADC data for runs 10, 11 and 12). | 
| 13 | -900 | 70, +ve | Tracker (C2) | 50pA/~10 kHz | 2 mm centred, 3.95mm PMMA | run13_2mmCCol_50pA_4mmPMMA | Tracker triggered, 3.95mm PMMA. | 
| 14 | -900 | 70, +ve | Tracker (C2) | 77pA/~10 kHz | 2 mm centred, 3.95mm PMMA | run14_2mmCCol_77pA_4mmPMMA | Repeat of run 13 (ADC data for runs 13, 14 and 15). | 
| 15 | -900 | 70, +ve | Tracker (C2) | 90pA/~10 kHz | 2 mm centred, 3.95mm PMMA | run15_2mmCCol_90pA_4mmPMMA | Repeat of run 13 (ADC data for runs 13, 14 and 15). | 
| 16 | -900 | 70, +ve | Tracker (C2) | 70pA/~10 kHz | 2 mm centred, 4.90mm PMMA | run16_2mmCCol_70pA_5mmPMMA | Tracker triggered, 4.90mm PMMA. Large current fluctuations: check shape of ADC spectrum. | 
| 17 | -900 | 70, +ve | Tracker (C2) | 65pA/~10 kHz | 2 mm centred, 4.90mm PMMA | run17_2mmCCol_65pA_5mmPMMA | Repeat of run 16 (ADC data for runs 16, 17 and 18). | 
| 18 | -900 | 70, +ve | Tracker (C2) | 60pA/~10 kHz | 2 mm centred, 4.90mm PMMA | run18_2mmCCol_60pA_5mmPMMA | Repeat of run 16 (ADC data for runs 16, 17 and 18). | 
| 19 | -900 | 70, +ve | Tracker (C2) | 50pA/~10 kHz | 2 mm centred, 5.70mm PMMA | run19_2mmCCol_50pA_6mmPMMA | Tracker triggered, 5.70mm PMMA. | 
| 20 | -900 | 70, +ve | Tracker (C2) | 50pA/~10 kHz | 2 mm centred, 5.70mm PMMA | run20_2mmCCol_50pA_6mmPMMA | Repeat of run 19 (ADC data for runs 19, 20 and 21). | 
| 21 | -900 | 70, +ve | Tracker (C2) | 60pA/~10 kHz | 2 mm centred, 5.70mm PMMA | run21_2mmCCol_60pA_6mmPMMA | Repeat of run 19 (ADC data for runs 19, 20 and 21). | 
| 22 | -900 | 70, +ve | Tracker (C2) | 90-140pA/~10 kHz | 2 mm with 6mm offset in +ve x, 5.70mm PMMA. | run22_2mmOSCol_100pA_6mmPMMA | Tracker triggered, 2 mm collimator with 6 mm offset in +ve x direction; 5.70 mm PMMA absorber. | 
| 23 | -900 | 70, +ve | Tracker (C2) | 85-120pA/~10 kHz | 2 mm with 6mm offset, 5.70mm PMMA | run23_2mmOSCol_100pA_6mmPMMA | Repeat of run 22 (ADC data for runs 22, 23 and 24). | 
| 24 | -900 | 70, +ve | Tracker (C2) | 10-75pA/~10 kHz | 2 mm with 6mm offset, 5.70mm PMMA | run24_2mmOSCol_70pA_6mmPMMA | Repeat of run 22 (ADC data for runs 22, 23 and 24). | 
| 25 | -900 | 70, +ve | Tracker (C2) | 40-50pA/~10 kHz | 2 mm pair, centres 12mm apart in x, 5.70mm PMMA | run25_2mmSBCol_40pA_6mmPMMA | Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction, 5.70 mm PMMA absorber. | 
| 26 | -900 | 70, +ve | Tracker (C2) | 45pA/~10 kHz | 2 mm pair, centres 12mm apart, 5.70mm PMMA | run26_2mmSBCol_45pA_6mmPMMA | Repeat of run 25 (ADC data for runs 25, 26 and 27). | 
| 27 | -900 | 70, +ve | Tracker (C2) | 45-55pA/~10 kHz | 2 mm pair, centres 12mm apart, 5.70mm PMMA | run27_2mmSBCol_50pA_6mmPMMA | Repeat of run 25 (ADC data for runs 25, 26 and 27). | 
| 28 | -900 | 70, +ve | Tracker (C2) | 70-90pA/~10 kHz | 2 mm with 6mm offset in +ve x. | run28_2mmOSCol_70pA_TrackTrig | Tracker triggered, 2 mm collimator with 6 mm offset in +ve x direction. | 
| 29 | -900 | 70, +ve | Tracker (C2) | 60pA/~10 kHz | 2 mm with 6mm offset | run29_2mmOSCol_60pA_TrackTrig | Repeat of run 28 (ADC data for runs 28, 29 and 30). | 
| 30 | -900 | 70, +ve | Tracker (C2) | 60pA/~10 kHz | 2 mm with 6mm offset | run30_2mmOSCol_60pA_TrackTrig | Repeat of run 28 (ADC data for runs 28, 29 and 30). | 
| 31 | -900 | 70, +ve | Tracker (C2) | 40-50pA/~10 kHz | 2 mm pair, centres 12mm apart in x. | run31_2mmSBCol_46pA_TrackTrig | Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction. | 
| 32 | -900 | 70, +ve | Tracker (C2) | 40-50pA/~10 kHz | 2 mm pair, centres 12mm apart | run32_2mmSBCol_45pA_TrackTrig | Repeat of run 31 (ADC data for runs 31, 32 and 33). | 
| 33 | -900 | 70, +ve | Tracker (C2) | 35-40pA/~10 kHz | 2 mm pair, centres 12mm apart | run33_2mmSBCol_40pA_TrackTrig | Repeat of run 31 (ADC data for runs 31, 32 and 33); large current dropout. | 
| 34 | -900 | 70, +ve | Tracker (C2) | 10pA/~10 kHz | 2 mm pair, centres 12mm apart in x. | run34_2mmSBCol_10pA_TrackTrig | Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; lower current repeat of 2 hole collimator. | 
| 35 | -900 | 70, +ve | Tracker (C2) | 10pA/~10 kHz | 2 mm pair, centres 12mm apart | run35_2mmSBCol_10pA_TrackTrig | Repeat of run 34 (ADC data for runs 34, 35 and 36). | 
| 36 | -900 | 70, +ve | Tracker (C2) | 8pA/~10 kHz | 2 mm pair, centres 12mm apart | run36_2mmSBCol_8pA_TrackTrig | Repeat of run 34 (ADC data for runs 34, 35 and 36). | 
| 37 | -900 | 70, +ve | Tracker (C2) | 20-24pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run37_2mmEPCol_20pA_4mmPMMA | Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; left-hand hole covered by 3.95&mm PMMA. | 
| 38 | -900 | 70, +ve | Tracker (C2) | 11pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run38_2mmEPCol_11pA_4mmPMMA | Repeat of run 37 (ADC data for runs 37, 38 and 39). | 
| 39 | -900 | 70, +ve | Tracker (C2) | 9pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run39_2mmEPCol_9pA_4mmPMMA | Repeat of run 37 (ADC data for runs 37, 38 and 39). | 
| 40 | -900 | 70, +ve | Tracker (C2) | 20-70pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run40_2mmEPCol_40pA_4mmPMMA | Tracker triggered, 2 mm hole pair collimator with centres 12 mm apart in x direction; left-hand hole covered by 3.95&mm PMMA. | 
| 41 | -900 | 70, +ve | Tracker (C2) | 40-120pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run41_2mmEPCol_40pA_4mmPMMA | Repeat of run 40 (ADC data for runs 40, 41 and 42); large current fluctuations. | 
| 42 | -900 | 70, +ve | Tracker (C2) | 15-45pA/~10 kHz | 2 mm pair, centres 12mm apart with 3.95mm PMMA over 1 hole. | run42_2mmEPCol_30pA_4mmPMMA | Repeat of run 40 (ADC data for runs 40, 41 and 42). |