| [http://www.hep.ucl.ac.uk/pbt/wikiData/images/Heidelberg_Nov2018/SingleModuleExperiment.png http://www.hep.ucl.ac.uk/pbt/wikiData/images/Heidelberg_Nov2018/SingleModuleExperiment.png] | [http://www.hep.ucl.ac.uk/pbt/wikiData/images/Heidelberg_Nov2018/SingleModuleExperiment.png http://www.hep.ucl.ac.uk/pbt/wikiData/images/Heidelberg_Nov2018/SingleModuleExperiment.png] | ||
| </div> | |||
| {| class="wikitable" | {| class="wikitable" | ||
Revision as of 10:14, 12 November 2018
2 night shifts with range calorimeter and single PMT module.
Equipment List
| Item | Notes | 
|---|---|
| Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm  | 
| DAQ desktop PC | |
| Control Laptop | |
| Ethernet Switcher | Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub. | 
| Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. | 
| Ethernet Cable x 2 | To connect DAQ PC to switcher, switcher to Network Hub. | 
Range Detector Experiment
| Item | Notes | 
|---|
Single Module Experiment
| Item | Notes | 
|---|---|
| Single Module Scintillator Blocks x5 | 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping. | 
| Photomultiplier Tube | Hamamatsu R13089 2" | 
| Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm  | 
| Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | 
| DAQ desktop PC | Controls Caen HV supply; records data from Caen digitiser. | 
| Caen NDT1470 HV Supply | Supplies HV to PMT | 
| USB Cable | Caen units to DAQ PC | 
| Male-to-Male SMA Cable x2 | Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector | 
| Female-to-Female SMA Connector | Connects Long SMA cable to Short/Light SMA cable. | 
| Male SMA to Male MCX Adaptor | Sends output from SMA cable to Digitiser | 
| Gloves | For handling scintillator | 
| Optical gel | For coupling scintillator to PMT | 
| Wipes | For removing optical gel | 
Experiment List
16–17th November
ISDI sensor + scintillator stack
17–18th November
Single module
Experiment Log
Beam Tests
16–17th November
| Run Number | High Voltage (V) | Trigger Level (mV) | Trigger Source | Beam Current / Rate | Collimator | Filename | Notes | 
|---|---|---|---|---|---|---|---|
| 00 | -900 | 70, +ve | Tracker (C2) | 170pA/~10 kHz | 2 mm centred | run00_2mmCCol_160pA_TrackTrig | First test of tracker/PMT synchronisation | 