ELogs/JeremyOcampo

From PBTWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Electronic Log for Jeremy Ocampo.

To do

  • New water tank setup
    • Scintillator sheet sandwiched between two water tanks replacing plastic blocks.
    • Optical grease in-between for smoothness (will scintillator be contaminated by the grease?)
    • Polish outer surfaces and lens
  • Figure out physics of green dis-coloration in high dose areas of plastic
  • Fill out wiki page for radiotherapy experimental runs
  • Get ML models to work on real images
  • Ask Stan for phd viva forms

Completed

2nd year


  • 1st term
    • G4 Separate Scintillation and Cerenkov photons in scintillator sheet simulation
      • Whole beam produces Cerenkov photons in the plastic slabs+scintillator sheet while Scintillation is only produced in the scintillator sheet.
      • A "scintillation only" image produces PDD, profile and Output factor within 2% of actual dose.
    • Birmingham Meeting 9th Dec With Adam, Simon, Geoff, Hamid, Spyros
      • Presented simulation results
      • Methods to separate Cerenkov and scintillation, concluded with:
        image plastic block (cerenkov) and then image scintillator sheet sandwiched by plastic slabs (scintillation + cerenkov) and then subtract
      • Plans for experiment in January with scintillator sheet sandwiched between plastic
      • Talked about using the system for treatment plan verification by comparing a video to simulation.
    • PhD transfer Report
    • PhD transfer Viva - passed yay
    • CDT presentation of 1st year work


1st year


  • Summer
    • Summer School STFC Data Intensive, Artificial Intelligence and Machine Learning Summer School 2019
    • G4 Simulate PDD, profile and Output factor from a scintillator sheet sandwiched between 2 platic slabs:
      • PDD agrees within 2% but profile and Output factor(OF) doesn't.
      • Cerenkov coming from plastic slabs distorts OF and profile.
      • This is because as you increase the beam width, the amount of X-ray going into the plastic slab is proportional to (beam width)2
        but the amount of X-rays going into the sheet is proportional to beam width.


  • 3rd term
    • Workshop Went to workshop - "Challenges and opportunities within practical small field dosimetry" - 9th may
    • G4 Simulate image of an irradiated scintillator block and compared it's pdd with image from CCD camera.
      • ~100,000 optical photons collected by lens given ~10,000,000 x-ray photons, which took 3 hours.
    • G4 Speed improvements of scintillator block image:
      • can use 4 lens' as there is 2 planes of symmetry => simulation captures 4x as much photons
      • Use HEP batch farm to run jobs on 100 cores
      • kill optical photons which would be internally reflected by all sides of block at there 1st step => simulation ~10x faster


  • 2nd term
    • Courses: Machine learning with big data, Inverse problems in imaging
    • Group placement project: exploring the simulacrum cancer dataset from PHE (partnered with Valtech)
      • presentation
      • report
    • G4 Import phase space file (cyberknife) beam to use as primary generator.
    • G4 Simulate PDD, profile dose distributions in water and compare with measured.



  • 1st term
    • Courses: Standard model 1 & 2, Prob and stats, Research software (python)
    • G4 Learning Geant4 with:
      • ED-Geant4 - Lectures with exercises and solutions from an intro G4 workshop in 2018.
      • Geant4 book - Reference for G4.