Proton Calorimetry/Meetings/2017/02/22

From PBTWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Minutes for UCL Proton Calorimetry Meeting, 22nd February 2017 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Anastasia Basharina-Freshville, Laurent Kelleter, Adam Knoetze, Matthieu Hentz

MSci reports due 27th March.

AK:

  • Working with pulser and LED.
  • Running LED pulser with regular pulse shape and spacing.
  • Seeing drops in ADC spectrum peak position from 7400 at 100Hz to 6400 at 5kHz.
  • During MedAustron visit will take data using detector emulator.

ABF:

  • Testing LED pulser to check whether variation in gain comes from LED or PMT.
  • After MedAustron will retest with super-stable SuperNEMO LEDs.
  • Taking signal from last dynode rather than anode to avoid final gain stage (~3.5) and saturation.
  • Long scintillator bars arrived from Nuvia:
    • Wrapped in mylar only to reduce amount of internal reflections.
    • Energy resolution worse: ~11% at 1MeV.
  • Preparing for MedAustron: MH and LK will prepare cables...
  • Housing needs modifying to fit long scintillator bar: need to make sure its light tight in case room lights cannot be switched off. LK suggests using a cardboard box...

MH:

  • Still no response from Clatterbridge and Carsten Welsch on PDFs of layout: SJ will chase it up.
  • Simulations of Clatterbridge beamline:
    • Tracking emittance evolution.
    • Initial beam parameters very large. Will use values from Hywel Owen:
      • σx = 4mm
      • σy = 4.5mm
      • σx' = 2.03mrad
      • σy' = 1.2mrad
    • Some particles seem to pass through metal shielding: LK suggests checking 3-dimensional structure of beamline.
    • Beamline support needs adding.

LK:

List of equipment for MedAustron

Hand Luggage

  • Scope
  • 2 PMTs + 1 base
  • DAQ laptop
  • Digitiser
  • HV unit
  • Scintillator bars

Hold

  • Collimators
  • Box
  • Signal cables
  • HV cables