Proton Calorimetry/Meetings/2017/11/29

From PBTWiki
Revision as of 15:30, 29 November 2017 by SimonJolly (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Minutes for UCL Proton Calorimetry Meeting, 22nd November 2017 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Ruben Saakyan, Laurent Kelleter, Anastasia Basharina-Freshville, Jordan Silverman, Dan Walker, Matthieu Hentz

ABF:

  • Fitting finally seems to work for single module spectrum:
    • Landau-Gaussian convolution with second degree polynomial.
    • ROOT requires specific order: fits Landau-Gaussian first.
    • Small features on the left of peak show extra 'wrinkle' which is not quite fitted; not present in July'15 data with UCL negative base.
    • Fit worse for MedAustron data but likely to be a result of pile-up.
    • FWHM from fit overestimates resolution slightly.
  • Hamamatsu provided quote for flat panel detectors:
    • Contact person Simon Whitehead.
    • Recommended C9730DK-10 with faster readout rate but larger noise.
    • Will ask for quote for C9728SK-10 and check which has larger dynamic range.
    • Will also check whether we can get demo model to test: full cost £16k + £2k for software.

MH:

  • Working on staged simulation to improve speed:
    • Large speed difference between good and bad nodes: trying to script finding fastest nodes...
    • Time limit of 12 hours for medium queue: some jobs overrun due to slow nodes and get ejected.
  • Also trying to visualise beam profile every 25mm:
    • Can't define overlapping geometries: need to include parallel world with sensitive detectors.
    • No response from Ben Morgan: will email Geant4 mailing list.
    • Sensitive detectors provide speed up over writing data in the stepping action.
  • Will look into getting Oyster cards for ENLIGHT meeting delegates.

RS:

  • Visit to Nuvia Monday/Tuesday:
    • Requested 100x100mm sheets, 2mm or 3mm thick depending on reliability of production.
    • Total thickness of 60mm
    • Nuvia produce a thick piece of scintillator, then squeeze under heat to correct thickness, then cut out sheet.
    • Previous issues result from lack of attention to pressing...
    • Samples will arrive before Christmas (perhaps not all...).
    • Hana about to go away on maternity leave...
  • Should be possible to cut and polish samples before they arrive:
    • Derek can cut some pieces from existing spares.
    • Georgio Savini and David Brooks should have expertise on polishing.
    • Nuvia may be able to polish themselves.

DW:

  • ROOT scripts for reading Lecroy binary files is now working.
    • Defines classes for acquiring and manipulating data.
    • Just got histogram spectrum working.
    • Will reject bad pulses and pulses with high variation in baseline.
    • Can output data to suitable file format.

JS:

  • Working on alternate fit for single module spectrum:
    • Fit uses Landau-Gaussian convolution with extra exponential part.
    • Χ2 per NDF above 5.
  • Not entirely dissimilar from Anastasia's fitting function...
  • Will review in a week.

LK:

  • All of last few weeks spent writing paper on Build-Up Effects in Proton Therapy:
    • Struggling to define protonic build-up in robust way.
    • Using 30% of Bragg peak good at high energy but poor at low energy.
    • Bortfeld formula works in opposite direction: would rather not use fit (need to check with Adam Gibson).
    • Have contacted Tracey Underwood to review paper.