Proton Calorimetry/Meetings/2018/02/07

From PBTWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Minutes for UCL Proton Calorimetry Meeting, 7th February 2018 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Ruben Saakyan, Matthieu Hentz, Jordan Silverman, Anastasia Basharina-Freshville, Laurent Kelleter

SJ:

  • Meeting with LK at TU Wien HEPHY on 1st February:
    • TU Wien have 26x26mm sensor developed for Belle they want to use for proton CT.
    • Sensor is very early in pCT development: readout is slow (~1,000 frames/s).
    • Potential for pCT collaboration.
    • They are sharing experimental time with us at MedAustron on 22/23 March.
    • We will have 6 hours on Thursday night and ~4 hours on Friday night.
    • Will make single module measurements for them: MedAustron rate and pCT calorimetry.
    • Accommodation is booked: 4 rooms in Orange Wings (close to MedAustron).
  • Both Zarges enclosures are finally here:
    • Smaller one is painted: waiting on specs from ISDI to choose patch panel connectors.
    • Larger one just arrived: Derek will paint tomorrow.

LK:

  • Running tests on Scintillator Sheets using LED:
    • First tests with Nikon DSLR carried out on 5/6 February.
    • Some sheets not properly painted, so light leaks in around fibre.
    • Camera highly adjustable: RS suggests running tests with LED settings used for PRIAPUS saturation.
    • Lens aberrations seen with high light levels.
    • Variation seen across sheet but average light level approximately the same for all sheets.
  • To Do:
    • Some sheets need repainting: will speak to Derek Attree.
    • Chasing up ISDI!
    • Test USB3 patch panel connector.
    • Finish off analysis.
    • Add Remote Desktop information to Wiki.

ABF:

  • To Do:
    • Continue LED tests: rerun with settings that saturated PRIAPUS; set up radioactive source.
    • Label scintillator sheets.
    • Polish scintillator sheets.
    • Analyse LED data.

RS:

  • Had meeting with Hamamatsu.
  • 2 potential products available:
    • Linear image sensor.
    • Position sensitive linear image sensor.
  • Both active pixel sensor strips.
  • Industrial devices: less than £50 each!
  • Readout available but expensive (£800).

MH:

  • Focussing on buffered event writing in Geant4 to speed up simulations.
  • Fixed issue by avoiding use of pointers: needed a custom accumulator class.
  • Factor of 30 speed up with buffering!
  • Code needs tidying up..
  • To Do:
    • Tidy up Geant4 buffering code.
    • Update Wiki.

JS: