Proton Calorimetry/Meetings/2020/12/02: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
(Created page with "== Minutes for UCL Proton Calorimetry Meetings, 25th November == === Present === '''Simon Jolly''', '''Raffaella Radogna''', '''Saad Shaikh''', '''Fern Pannell''' === [[ELogs/...")
 
No edit summary
Line 1: Line 1:
== Minutes for UCL Proton Calorimetry Meetings, 25th November ==
== Minutes for UCL Proton Calorimetry Meetings, 2nd December ==


=== Present ===
=== Present ===
Line 8: Line 8:


=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
*Took further measurements at UCL with Raffy using DDC232 board. Office measurements still noisy, so need to figure out how to shield electronics.
*Will take light measurements at home using UV torch.
**Will take light measurements at home using UV torch.
*Created live version of Laurent's ROOT quenched Bragg fit – tested with data from HIT April 2019 converted into hexadecimal format to simulate photodiode data.
**Can achieve roughly 3.5 FPS if binned fit is not chosen.
**Will see if macro can be optimised further.
*Will compare readout speeds of DDC232, DDC316 and DDC118 for full size detector. Will assume 1:1 photodiode to input mapping.
*USB interface will require using libftdi on Windows, in order to use ILA for debugging while capturing data. Currently unsure if this is possible.
*Laptop has been purchased using Raffy's hardware grant. Simon still happy for me to keep it. :)
**Remaining £1k from HEP could be put towards a laptop later down the line.


=== [[ELogs/FernPannell|Fern Pannell]] ===
=== [[ELogs/FernPannell|Fern Pannell]] ===

Revision as of 17:44, 2 December 2020

Minutes for UCL Proton Calorimetry Meetings, 2nd December

Present

Simon Jolly, Raffaella Radogna, Saad Shaikh, Fern Pannell

Raffaella Radogna

Saad Shaikh

  • Took further measurements at UCL with Raffy using DDC232 board. Office measurements still noisy, so need to figure out how to shield electronics.
    • Will take light measurements at home using UV torch.
  • Created live version of Laurent's ROOT quenched Bragg fit – tested with data from HIT April 2019 converted into hexadecimal format to simulate photodiode data.
    • Can achieve roughly 3.5 FPS if binned fit is not chosen.
    • Will see if macro can be optimised further.
  • Will compare readout speeds of DDC232, DDC316 and DDC118 for full size detector. Will assume 1:1 photodiode to input mapping.
  • USB interface will require using libftdi on Windows, in order to use ILA for debugging while capturing data. Currently unsure if this is possible.
  • Laptop has been purchased using Raffy's hardware grant. Simon still happy for me to keep it. :)
    • Remaining £1k from HEP could be put towards a laptop later down the line.

Fern Pannell