		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=356</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=356"/>
		<updated>2016-08-18T20:43:04Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Calibration wheel */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1 hr.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Neutron measurements ===&lt;br /&gt;
&lt;br /&gt;
Neutron measurements taken using the large hexagonal scintillator block with 8&amp;quot; PMT (Hex module).&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=355</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=355"/>
		<updated>2016-08-18T15:50:33Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Off-axis collimator tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1 hr.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Neutron measurements ===&lt;br /&gt;
&lt;br /&gt;
Neutron measurements taken using the large hexagonal scintillator block with 8&amp;quot; PMT (Hex module).&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=354</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=354"/>
		<updated>2016-08-18T15:50:02Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[LUNCH] - approx. 1 hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Neutron measurements ===&lt;br /&gt;
&lt;br /&gt;
Neutron measurements taken using the large hexagonal scintillator block with 8&amp;quot; PMT (Hex module).&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=353</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=353"/>
		<updated>2016-08-18T15:49:15Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 2 (August 3rd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[LUNCH] - approx. 1 hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Neutron measurements ===&lt;br /&gt;
&lt;br /&gt;
Neutron measurements taken using the large hexagonal scintillator block with 8&amp;quot; PMT (Hex module).&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs&amp;diff=352</id>
		<title>Proton Calorimetry/Experimental Runs</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs&amp;diff=352"/>
		<updated>2016-08-18T15:46:35Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* 2016 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Information is available for the following experimental runs:&lt;br /&gt;
&lt;br /&gt;
== [[/2016|2016]] ==&lt;br /&gt;
&lt;br /&gt;
; [[/2016/Aug2-3|2nd+3rd August 2016]]&lt;br /&gt;
* To obtain energy-to-range calibration measurements with a calibration wheel used by physicists at Clatterbridge with detector module comprising a 2&amp;quot; PMT and new PS-based scintillator.&lt;br /&gt;
* To obtain data cross-checking measurements taken with the wheel to that taken with PMMA blocks of equivalent thickness at the same location, and further upstream at the modulator box.&lt;br /&gt;
* To record total dose delivered to the new PS-based scintillator for radiation damage and hardness considerations.&lt;br /&gt;
* To record waveform data with new LeCroy HDO6104 oscilloscope.&lt;br /&gt;
* To record neutron measurements with the large 8&amp;quot; PMT hexagonal block module.&lt;br /&gt;
&lt;br /&gt;
== [[/2015|2015]] ==&lt;br /&gt;
&lt;br /&gt;
; [[/2015/Dec21-22|21st-22nd December 2015]]&lt;br /&gt;
: Give short explanation of the purpose and results.&lt;br /&gt;
; [[/2015/Jul8-9|8th-9th July 2015]]&lt;br /&gt;
: Give short explanation of the purpose and results.&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=351</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=351"/>
		<updated>2016-08-18T15:44:22Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 2 (August 3rd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[LUNCH] - approx. 1 hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=350</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=350"/>
		<updated>2016-08-18T15:43:43Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Calibration wheel (fine) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 093 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 094 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 095 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 110 || ADC || 096 || ~1,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 097 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 098 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 099 || ~1,200 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 100 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 101 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 102 || ~1,500 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 0.2&amp;amp;nbsp;MU. Dose B: 0.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 27.71&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=349</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=349"/>
		<updated>2016-08-18T15:20:07Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
Note: Construction going on in room next to control room.&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=348</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=348"/>
		<updated>2016-08-18T15:17:32Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Calibration wheel (fine) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 169 || ADC || 081 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 171 || ADC || 082 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 083 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 084 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 176 || ADC || 082 || ~23 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 || ADC || 086 || ~23 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 162 || ADC || 087 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 158 || ADC || 088 || ~200 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 089 || ~100 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 155 || ADC || 090 || ~1,000 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 151|| ADC || 091 || ~700 in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 145 || ADC || 092 || ~900 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 2.0&amp;amp;nbsp;MU. Dose B: 2.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 45.39&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=347</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=347"/>
		<updated>2016-08-18T15:12:08Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: &amp;amp;nbsp;MU. Dose B: &amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; &amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=346</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=346"/>
		<updated>2016-08-18T15:11:42Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: &amp;amp;nbsp;MU. Dose B: &amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; &amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=345</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=345"/>
		<updated>2016-08-18T15:09:46Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Calibration wheel (fine) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
wd: ham_stdCub/1.98mm/wheel&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| ADC || 0 || 079 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: &amp;amp;nbsp;MU. Dose B: &amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; &amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=344</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=344"/>
		<updated>2016-08-18T15:07:04Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 2 (August 3rd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel (fine) ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
* Rate: 9-10&amp;amp;nbsp;kHz&lt;br /&gt;
* I: 150.2&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
|&lt;br /&gt;
* Collimator: 1.98&amp;amp;nbsp;mm&lt;br /&gt;
* Foil current: 0.002-0.0025&amp;amp;nbsp;nA&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
* Gas source: 0.6&amp;amp;nbsp;cc/min&lt;br /&gt;
| 0 || 079 || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (on the Bragg peak) || ADC || 080 || ~25 in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: &amp;amp;nbsp;MU. Dose B: &amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; &amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=343</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=343"/>
		<updated>2016-08-18T14:54:41Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
| ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=342</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=342"/>
		<updated>2016-08-18T14:53:55Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Wheel calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Calibration wheel ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=341</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=341"/>
		<updated>2016-08-18T14:52:31Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Off-axis collimator tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=340</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=340"/>
		<updated>2016-08-18T14:50:24Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Off-axis collimator tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6200 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC &amp;amp;mu;:~6150 || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.3&amp;amp;nbsp;nA || ADC || 72 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.7&amp;amp;nbsp;GB) || 73 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 110&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;bottom&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.1-1.2&amp;amp;nbsp;nA || ADC || 74 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 75 ||&lt;br /&gt;
|-&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). || ADC || 76 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 100&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;I: 150.3&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;ADC &amp;amp;mu;:~2450 || Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;16&amp;amp;nbsp;mm&amp;lt;/u&amp;gt; off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.0-1.1&amp;amp;nbsp;nA || ADC || 77 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.8&amp;amp;nbsp;GB) || 78 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 411.1&amp;amp;nbsp;MU. Dose B: 408.5&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 24.04&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=339</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=339"/>
		<updated>2016-08-18T14:18:20Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Off-axis collimator tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (&amp;lt;u&amp;gt;centre&amp;lt;/u&amp;gt;/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;left&amp;lt;/u&amp;gt; of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6150) || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6200) || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=338</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=338"/>
		<updated>2016-08-18T14:13:50Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Off-axis collimator tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (centre/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, left of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6150) || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6200) || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=337</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=337"/>
		<updated>2016-08-18T14:12:01Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 2 (August 3rd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 64 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Off-axis collimator tests ===&lt;br /&gt;
&lt;br /&gt;
wd: /ham_stdCub/0.5mm&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt; Dose monitor control reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || After adjustment: &lt;br /&gt;
*Rate: 150kHz&lt;br /&gt;
*I: 150.7&amp;amp;nbsp;&amp;amp;mu;A&lt;br /&gt;
| Collimator: 0.5&amp;amp;nbsp;mm (centre/on axis)&lt;br /&gt;
Beam start:&lt;br /&gt;
*Foil current: 0.8&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 1.6&amp;amp;nbsp;mA&lt;br /&gt;
*Gas source: 1&amp;amp;nbsp;cc/min&lt;br /&gt;
&lt;br /&gt;
After adjustment:&lt;br /&gt;
*Foil current: 1.6&amp;amp;nbsp;nA (cycling from 0)&lt;br /&gt;
*Arc current: 2&amp;amp;nbsp;mA&lt;br /&gt;
| ADC ||  || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 230kHz &amp;lt;br&amp;gt;Dose rate: 23&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || Foil current: ~1.6&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC || 66 || ~5,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 67 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 257.0&amp;amp;nbsp;MU. Dose B: 255.3&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 13.66&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250kHz &amp;lt;br&amp;gt;I: 151.6&amp;amp;nbsp;&amp;amp;mu;A || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, left of centre (into the beam)). Note: Scintillator is centred for resulting collimator each time. &amp;lt;br&amp;gt;Foil current: ~1.8-1.4&amp;amp;nbsp;nA Arc current: 2&amp;amp;nbsp;mA&amp;lt;br&amp;gt;Gas source: 0.6&amp;amp;nbsp;cc/min || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6150) || 68 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 69 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Collimator: 0.5&amp;amp;nbsp;mm (8&amp;amp;nbsp;mm off-axis, &amp;lt;u&amp;gt;top&amp;lt;/u&amp;gt; of centre). &amp;lt;br&amp;gt;Foil current: ~1.4&amp;amp;nbsp;nA || ADC &amp;lt;br&amp;gt;(&amp;amp;mu;~6200) || 70 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.5&amp;amp;nbsp;GB) || 71 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 349.4.0&amp;amp;nbsp;MU. Dose B: 347.1&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 16.36&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=336</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=336"/>
		<updated>2016-08-18T11:20:36Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 5.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 173&amp;amp;nbsp;&amp;amp;mu;A || Foil current: &amp;lt;u&amp;gt;0.35&amp;lt;/u&amp;gt;-0.4&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.6&amp;amp;nbsp;mA || ADC || 62 || ~2,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2.1&amp;amp;nbsp;GB) || 65 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 126.9&amp;amp;nbsp;MU. Dose B: 126.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 69.28&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=335</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=335"/>
		<updated>2016-08-18T11:08:17Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 150.55&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak. Increased gas flow: No change when increased to 0.80&amp;amp;nbsp;cc/min. Foil current decreased when increased to 1.0&amp;amp;nbsp;cc/min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 59 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Dose rate: 1.7&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 151.4&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.120-130&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1&amp;amp;nbsp;mA || ADC || 60 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 61 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Rate: 500&amp;amp;nbsp;kHz (current) &amp;lt;br&amp;gt;Dose rate: 2.8&amp;amp;nbsp;MU/min &amp;lt;br&amp;gt;I: 152.25&amp;amp;nbsp;&amp;amp;mu;A || Foil current: 0.2&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 1.3&amp;amp;nbsp;mA || ADC || 62 || ~10,000 events in peak. Increased arc current.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 63 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=334</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=334"/>
		<updated>2016-08-18T10:51:36Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min || &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=333</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=333"/>
		<updated>2016-08-18T10:49:15Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Dose rate: 0-0.1&amp;amp;nbsp;MU/min || 1.98&amp;amp;nbsp;mm collimator Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Threshold: -40&amp;amp;nbsp;kHz to match digitiser) ||  || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 170&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.066-68&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Dose rate: 0.9&amp;amp;nbsp;MU/min || &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A || ADC || 56 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.4&amp;amp;nbsp;GB) || 57 || &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 125&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0042&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Dose rate: 0.5&amp;amp;nbsp;MU/min || &amp;lt;br&amp;gt;Arc current: 500&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 1.0&amp;amp;nbsp;cc/min || ADC || 58 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=332</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=332"/>
		<updated>2016-08-18T10:36:36Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz || 1.98&amp;amp;nbsp;mm collimator &amp;lt;br&amp;gt;Foil current: 0.0016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 8&amp;amp;nbsp;kHz ||  || waveforms || 55 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=331</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=331"/>
		<updated>2016-08-18T10:33:38Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz ||  Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz || Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
| Before rate drop&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz || Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz || Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) || I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || 1.98&amp;amp;nbsp;mm collimator || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || 1.98&amp;amp;nbsp;mm collimator || ADC || 41 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=330</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=330"/>
		<updated>2016-08-18T10:28:26Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests (continued) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 6-7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0016&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Gas source: 0.39&amp;amp;nbsp;cc/min || 1.98&amp;amp;nbsp;mm collimator || ADC || 54 || ~5,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || 1.98&amp;amp;nbsp;mm collimator || ADC || 41 || &lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=329</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=329"/>
		<updated>2016-08-18T01:37:05Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 2 (August 3rd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests (continued) ===&lt;br /&gt;
&lt;br /&gt;
1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A || 1.98&amp;amp;nbsp;mm collimator || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=328</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=328"/>
		<updated>2016-08-17T20:27:37Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf datasheet] PDF | 1.4&amp;amp;nbsp;MB&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=327</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=327"/>
		<updated>2016-08-17T20:22:49Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf Datasheet] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=326</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=326"/>
		<updated>2016-08-17T20:19:17Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run/digitiser file number equivalents !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=325</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=325"/>
		<updated>2016-08-17T20:18:20Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run number equivalent !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 032, 034 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 12&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_12kHzrate || 00-50: binary || 035, 036 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || 20&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_20kHzrate || 00-50: binary || 037, 038 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 13.4&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || 7&amp;amp;nbsp;kHz || 1.98mmcol_13.4mmabs_7kHzrate || 00-50: binary || 039, 040 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 20&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_20kHzrate || 00-050: binary || 041, 042 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 50&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_50kHzrate || 00-050: binary || 043, 044 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 85&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_85kHzrate || 00-050: binary || 045, 046 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 140&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_140kHzrate || 00-050: binary || 047, 048 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 250&amp;amp;nbsp;kHz || 1.98mmcol_ratetest_250kHzrate || 00-050: binary || 049, 050 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || none || N/A || 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;500&amp;amp;nbsp;kHz (based on scattering foil current) || 1.98mmcol_ratetest_500kHzrate || 00-050: binary || 051, 053 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=324</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=324"/>
		<updated>2016-08-17T20:02:35Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run number equivalent !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || Rate: 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Same position modulator wheel was. || Rate: 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 41 || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Upsteam in usual position inside modulator box. || Rate: 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 41 || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=323</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=323"/>
		<updated>2016-08-17T20:01:27Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~-77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Absorber!! Position !! Rate !! File directory !! File number &amp;amp; data recorded !! Run number equivalent !! Comments&lt;br /&gt;
|- &lt;br /&gt;
| -900 || none || N/A || Rate: 20&amp;amp;nbsp;kHz || 1.98mmcol_noabs_25kHzrate || 0-1: ASCII &amp;lt;br&amp;gt;00-49: binary ||  || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || Position of wheel (downstream of nozzle) || Rate: 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 41 || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
| -900 || 7.24&amp;amp;nbsp;mm PMMA || In modulator box || Rate: 25&amp;amp;nbsp;kHz || 1.98mmcol_7.24mmabs_25kHzrate || 00-051: binary || 41 || Trigger threshold: -75&amp;amp;nbsp;mV&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=322</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=322"/>
		<updated>2016-08-17T19:21:24Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~.77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate !! File directory !! Data recorded !! File number !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 ||&lt;br /&gt;
&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=321</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=321"/>
		<updated>2016-08-17T19:21:09Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf] |1.4 MB}}&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~.77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate !! File directory !! Data recorded !! File number !! Run number !! Comments&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 ||&lt;br /&gt;
&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=320</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=320"/>
		<updated>2016-08-17T19:14:41Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* LeCroy scope data */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
Pulse parameters:&lt;br /&gt;
* ~500&amp;amp;nbsp;mV&lt;br /&gt;
*Threshold of ~.77&amp;amp;nbsp;mV.&lt;br /&gt;
*Note: Slight reflection seen at ~350&amp;amp;nbsp;ns after main pulse, which is equivalent to ~10&amp;amp;nbsp;m (given that the speed of light in a cable is ~4&amp;amp;nbsp;ns/m).&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=319</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=319"/>
		<updated>2016-08-17T15:39:27Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 300&amp;amp;nbsp;kHz (scope) &amp;lt;br&amp;gt;Foil current: 0.25-0.27&amp;amp;nbsp;nA --&amp;gt; 500&amp;amp;nbsp;kHz (extrapolated) &amp;lt;br&amp;gt;I: 170.5&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;Arc current: 1.2&amp;amp;nbsp;mA ||  || ADC || 51 || ~300 events in peak. Pile-up seen in ADC spectrum.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current:  0.20-0.27&amp;amp;nbsp;nA &amp;lt;br&amp;gt;I: 171.2&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 53 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 134.7&amp;amp;nbsp;MU. Dose B: 134.2&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 92.22&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=318</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=318"/>
		<updated>2016-08-17T15:26:10Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150;&amp;amp;mu;A&lt;br /&gt;
*I: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 250&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: Dropped from 0.1080&amp;amp;nbsp;nA to 0.1050&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 800&amp;amp;nbsp;&amp;amp;mu;A &amp;lt;br&amp;gt;I: 151.3&amp;amp;nbsp;&amp;amp;mu;A  ||  || ADC || 49 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current and rate went down over time. Arc current down to 700&amp;amp;nbsp;&amp;amp;mu;A ||  || waveforms &amp;lt;br&amp;gt;(~2&amp;amp;nbsp;GB) || 50 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=317</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=317"/>
		<updated>2016-08-17T15:01:26Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
&lt;br /&gt;
* Wheel segments are each ~4&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between collimator exit (downstream face of collimator) and the start of the wheel (the upstream face) is 37.5&amp;amp;nbsp;mm.&lt;br /&gt;
* Distance between the black box edge and upstream edge of the wheel is 41&amp;amp;nbsp;mm.&lt;br /&gt;
&lt;br /&gt;
Electronic equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=316</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=316"/>
		<updated>2016-08-17T13:13:10Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 46 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 140&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0500&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 400&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 47 || ~15,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Foil current: Dropped from ~0.0450&amp;amp;nbsp;nA to 0.0370&amp;amp;nbsp;nA ||  || waveforms &amp;lt;br&amp;gt;(~1.6&amp;amp;nbsp;GB) || 48 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=315</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=315"/>
		<updated>2016-08-17T13:09:20Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Dose rate: 0.4 - 0.5. &amp;lt;br&amp;gt;Before rate drop&lt;br /&gt;
*Rate: 85&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0250&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 150.5;&amp;amp;mu;A&lt;br /&gt;
&lt;br /&gt;
After rate drop&lt;br /&gt;
*Rate: 90&amp;amp;nbsp;kHz&lt;br /&gt;
*Foil current: 0.0300&amp;amp;nbsp;nA&lt;br /&gt;
*Arc current: 200;&amp;amp;mu;A&lt;br /&gt;
|  || ADC || 45 || ~10,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=314</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=314"/>
		<updated>2016-08-17T13:01:45Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Rate tests */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
All PMMA absorbers removed from beam. 1.98&amp;amp;nbsp;mm collimator still in place.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.005&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 50&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 41 || ~7,000 events in peak. No absorbers in beam.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 42 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 43 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 44 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 50&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;Foil current: 0.0125&amp;amp;nbsp;nA &amp;lt;br&amp;gt;Arc current: 75&amp;amp;nbsp;&amp;amp;mu;A ||  || ADC || 45 || ~7,000 events in peak. Increased arc current to up the rate.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;7&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=313</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=313"/>
		<updated>2016-08-16T21:29:33Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* PMMA modulator block cross-check */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak. Beam misbehaviour (shifting) starting with this run and onwards.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=312</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=312"/>
		<updated>2016-08-16T21:24:40Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== LeCroy scope data ===&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=311</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=311"/>
		<updated>2016-08-16T21:21:41Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=== Rate tests ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=310</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=310"/>
		<updated>2016-08-16T20:18:49Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Day 1 (August 2nd) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 6.7&amp;amp;nbsp;MU. Dose B: 6.9&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 94.19&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=309</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=309"/>
		<updated>2016-08-16T20:16:55Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* PMMA modulator block cross-check */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB) || 31 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 38 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~7&amp;amp;nbsp;kHz &amp;lt;br&amp;gt;ADC: ~4900 &amp;lt;br&amp;gt;After beam shift ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 39 || ~5,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 13.4&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 40 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=308</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=308"/>
		<updated>2016-08-16T19:51:08Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* PMMA modulator block cross-check */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms || 31 &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB)||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~12&amp;amp;nbsp;kHz ||  || 7.24&amp;amp;nbsp;mm || Upsteam in usual position inside modulator box. || ADC || 35 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1.1&amp;amp;nbsp;GB) || 36 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || ADC: ~4373 &amp;lt;br&amp;gt;After beam shift &amp;lt;br&amp;gt;Rate: ~20&amp;amp;nbsp;kHz ||  || 13.4&amp;amp;nbsp;mm (corresponding to wheel step 80; 15.6&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 37 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>
	</entry>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=307</id>
		<title>Proton Calorimetry/Experimental Runs/2016/Aug2-3</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Experimental_Runs/2016/Aug2-3&amp;diff=307"/>
		<updated>2016-08-16T19:39:10Z</updated>

		<summary type="html">&lt;p&gt;HiuFungWong: /* Wheel calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dose calibration at Clatterbridge: 0.9 Gy per monitor unit (MU) at 60 MeV.&lt;br /&gt;
&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
== Day 1 (August 2nd)==&lt;br /&gt;
&lt;br /&gt;
=== Wheel calibration ===&lt;br /&gt;
Equipment setup:&lt;br /&gt;
* DC offset: -30&amp;amp;nbsp;mV&lt;br /&gt;
* Record length: 456&amp;amp;nbsp;ns&lt;br /&gt;
* Threshold: 40&amp;amp;nbsp;LSB&lt;br /&gt;
* Trigger: 194&amp;amp;nbsp;mV&lt;br /&gt;
* Gate offset: 10&amp;amp;nbsp;ns&lt;br /&gt;
* Pre-trigger: 50&amp;amp;nbsp;ns&lt;br /&gt;
* Charge sensitivity: 20&amp;amp;nbsp;fc/LSB&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! Wheel step position !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST&lt;br /&gt;
|&lt;br /&gt;
Beam off:&lt;br /&gt;
* I: 150.51&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
Beam on:&lt;br /&gt;
* Rate: 300&amp;amp;nbsp;kHz on startup.&lt;br /&gt;
* Rate: 25&amp;amp;nbsp;kHz at -100&amp;amp;nbsp;mV.&lt;br /&gt;
| 1.98&amp;amp;nbsp;mm&lt;br /&gt;
Beam startup:&lt;br /&gt;
* Arc current: 750&amp;amp;nbsp;mV&lt;br /&gt;
* Gas source: 0.67&amp;amp;nbsp;cc/min&lt;br /&gt;
Beam settings change:&lt;br /&gt;
* Arc current: 50&amp;amp;nbsp;&amp;amp;mu;&lt;br /&gt;
* Gas source: 0.39&amp;amp;nbsp;cc/min&lt;br /&gt;
* Dose rate: 0.1&amp;amp;nbsp;MU/min&lt;br /&gt;
| N/A || || [startup] || Beam startup and calibration&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 01 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || waveforms || 03 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 20 || ADC || 05 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 40 || ADC || 06 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 60 || ADC || 07 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 80 || ADC || 08 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || ADC || 09 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~0.5&amp;amp;nbsp;GB) || 11 || Beam dropped. Repeat in Run 13.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 100 || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 13 || Repeat of Run 10.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 120 || ADC || 14 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 140 || ADC || 15 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 160 || ADC || 16 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 130 || ADC || 17 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 150 || ADC || 18 || ~6,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 165 (Just before Bragg peak, which is at wheel step 166.)|| ADC || 19 || ~6,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 20 || Beam dropped. ~4,000 events in peak. Repeat in Run 21.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 170 || ADC || 21 || Repeat of Run 20. ~4,000 events in peak. &lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 (Bragg peak fall-off area.) || ADC || 22 || Beam dropped. Repeat in Run 23.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 173 || ADC || 23 || Repeat of Run 22. ~1.800 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 175 || ADC || 24 ||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 179 || ADC || 25 || ~30 events in peak. No &amp;quot;peak&amp;quot; apparent; potentially only secondaries.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 167 (Tip of Bragg peak.) || ADC || 26 || ~7,000 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 25&amp;amp;nbsp;kHz (1,000 events in 45&amp;amp;nbsp;ms) ||  || 0 || ADC || 27 || ~7,000 events in peak. Back to starting point on calibration wheel to compare with Run 01.&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;8&amp;quot; style=&amp;quot;background:#ffcccc&amp;quot; | BEAM OFF. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Integrated dose:&amp;lt;/b&amp;gt; Dose A: 36.7&amp;amp;nbsp;MU. Dose B: 36.6&amp;amp;nbsp;MU. &amp;lt;br&amp;gt;&amp;lt;b&amp;gt;Total beam time run:&amp;lt;/b&amp;gt; 99&amp;amp;nbsp;min.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || ADC || 28 || Background run. Acquisition left over lunch. ~140 events in peak.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[&amp;lt;b&amp;gt;LUNCH&amp;lt;/b&amp;gt;] - approx. 1&amp;amp;nbsp;hr.&lt;br /&gt;
&lt;br /&gt;
=== PMMA modulator block cross-check ===&lt;br /&gt;
&lt;br /&gt;
PMMA modulator blocks of thickness equivalent to particular steps of calibration wheel inserted into beamline at location of wheel (just downstream of nozzle) and upstream inside modulator box to cross-check against data obtained earlier using calibration wheel.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! High voltage&amp;lt;br&amp;gt;(V) !! Trigger !! Rate &amp;amp; additional information !! Collimator size &amp;amp; beam information !! PMMA thickness &amp;lt;br&amp;gt;(mm) !! Position of PMMA block !! Data recorded !! Run number !! Comments&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;center&amp;quot; colspan=&amp;quot;9&amp;quot; style=&amp;quot;background:#ccffcc&amp;quot; | BEAM ON. &amp;lt;br&amp;gt;Dose monitor operation reset.&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: 20&amp;amp;nbsp;kHz || Threshold: 40&amp;amp;nbsp;LSB || 0 (No PMMA. Calibration wheel removed.) || N/A || ADC || 29 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 0 || N/A || waveforms || 31 &amp;lt;br&amp;gt;(~1.2&amp;amp;nbsp;GB)||&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST ||  ||  || 7.24&amp;amp;nbsp;mm (corresponding to wheel step 40; 8.3&amp;amp;nbsp;mm water) || Same position the calibration wheel was. || ADC || 32 || ~7,000 events in peak&lt;br /&gt;
|-&lt;br /&gt;
| -900 || ST || Rate: ~25&amp;amp;nbsp;kHz ||  || 0 || Same position the calibration wheel was. || waveforms &amp;lt;br&amp;gt;(~1&amp;amp;nbsp;GB) || 34 ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Day 2 (August 3rd) ==&lt;br /&gt;
&lt;br /&gt;
Scope 2: LeCroy HDO6104 [http://teledynelecroy.com/oscilloscope/oscilloscopemodel.aspx?modelid=7170&amp;amp;capid=102&amp;amp;mid=504], Datasheet {{PDFlink | [http://cdn.teledynelecroy.com/files/pdf/hdo6000_oscilloscope_datasheet.pdf ] |1.4 MB}}&lt;/div&gt;</summary>
		<author><name>HiuFungWong</name></author>