<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?action=history&amp;feed=atom&amp;title=Proton_Calorimetry%2FMeetings%2F2018%2F01%2F31</id>
	<title>Proton Calorimetry/Meetings/2018/01/31 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?action=history&amp;feed=atom&amp;title=Proton_Calorimetry%2FMeetings%2F2018%2F01%2F31"/>
	<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Meetings/2018/01/31&amp;action=history"/>
	<updated>2026-04-21T15:45:33Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Meetings/2018/01/31&amp;diff=1270&amp;oldid=prev</id>
		<title>SimonJolly: Created page with &quot;== Minutes for UCL Proton Calorimetry Meeting, 31st January 2018 (D17, Physics &amp; Astronomy, UCL) ==  === Present ===  &#039;&#039;&#039;Simon Jolly&#039;&#039;&#039;, &#039;&#039;&#039;Ruben Saakyan&#039;&#039;&#039;, &#039;&#039;&#039;Matthieu Hentz&#039;&#039;&#039;...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.hep.ucl.ac.uk/pbt/pbtWiki/index.php?title=Proton_Calorimetry/Meetings/2018/01/31&amp;diff=1270&amp;oldid=prev"/>
		<updated>2018-01-31T14:44:25Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;== Minutes for UCL Proton Calorimetry Meeting, 31st January 2018 (D17, Physics &amp;amp; Astronomy, UCL) ==  === Present ===  &amp;#039;&amp;#039;&amp;#039;Simon Jolly&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Ruben Saakyan&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Matthieu Hentz&amp;#039;&amp;#039;&amp;#039;...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Minutes for UCL Proton Calorimetry Meeting, 31st January 2018 (D17, Physics &amp;amp; Astronomy, UCL) ==&lt;br /&gt;
&lt;br /&gt;
=== Present ===&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Simon Jolly&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Ruben Saakyan&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Matthieu Hentz&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Jordan Silverman&amp;#039;&amp;#039;&amp;#039;, &amp;#039;&amp;#039;&amp;#039;Dan Walker&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;DW&amp;#039;&amp;#039;&amp;#039;:&lt;br /&gt;
* Making progress with [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2018/DW_LeCroyData_31-01-18.pptx extracting data from Leroy binary files]:&lt;br /&gt;
** Aim is to load LeCroy waveform files, identify pile-up, calculate ADC counts and do it quickly.&lt;br /&gt;
** Previously used &amp;amp;chi;&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; for selecting bad pulses; Schmitt trigger on rising edge faster.&lt;br /&gt;
** Integrating whole pulse gives broader peak with larger mean than Caen.&lt;br /&gt;
** Shortening integration window makes LeCroy peak match with Caen, even for low counts.&lt;br /&gt;
* &amp;#039;&amp;#039;To Do&amp;#039;&amp;#039;:&lt;br /&gt;
** Update information on Wiki.&lt;br /&gt;
** Badger &amp;#039;&amp;#039;&amp;#039;Tony Price&amp;#039;&amp;#039;&amp;#039; for tracker files!!.&lt;br /&gt;
** Work out how to calculate incoming trigger rate for LeCroy scope.&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;JS&amp;#039;&amp;#039;&amp;#039;:&lt;br /&gt;
* Reanalysed scintillator sheet thicknesses:&lt;br /&gt;
** 3&amp;amp;nbsp;mm sheets are closer to 2.75&amp;amp;nbsp;mm but variation is mostly below 100 microns.&lt;br /&gt;
** 2&amp;amp;nbsp;mm sheets have 2 groupings:&lt;br /&gt;
** 2.0&amp;amp;nbsp;mm group has better flatness than 2.6&amp;amp;nbsp;mm group.&lt;br /&gt;
** Thickness sigma of 3&amp;amp;nbsp;mm sheets 90% below 30 micron target.&lt;br /&gt;
* Continuing to work on Clatterbridge simulations:&lt;br /&gt;
** Needs a list of things to do!&lt;br /&gt;
* &amp;#039;&amp;#039;To Do&amp;#039;&amp;#039;:&lt;br /&gt;
** Write up scintillator sheet measurements and post iPython notebook with analysis.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;MH&amp;#039;&amp;#039;&amp;#039; will but &amp;#039;&amp;#039;&amp;#039;JS&amp;#039;&amp;#039;&amp;#039; in touch with &amp;#039;&amp;#039;&amp;#039;Jactina Yap&amp;#039;&amp;#039;&amp;#039; to include more components in beamline.&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;MH&amp;#039;&amp;#039;&amp;#039;:&lt;br /&gt;
* Update from &amp;#039;&amp;#039;&amp;#039;Jacinta Yap&amp;#039;&amp;#039;&amp;#039; on Clatterbridge:&lt;br /&gt;
** Spoken to Andrzej Kacperek about positions of cap and nozzle: positions and locations shouldn&amp;#039;t make difference to treatment.&lt;br /&gt;
** Dose monitor foils are 20 microns with air gap in between of 2&amp;amp;nbsp;mm.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Jacinta&amp;#039;&amp;#039;&amp;#039; needs to know input parameters, particularly energy and energy spread.&lt;br /&gt;
* Trying to replicate bug in buffered readout for Geant4.&lt;br /&gt;
* Currently compiling Geant4 on Virtual Machine on &amp;#039;&amp;#039;&amp;#039;new&amp;#039;&amp;#039;&amp;#039; MacBook.&lt;br /&gt;
* &amp;#039;&amp;#039;To Do&amp;#039;&amp;#039;:&lt;br /&gt;
** Buffering of readout in Geant4.&lt;br /&gt;
** Put &amp;#039;&amp;#039;&amp;#039;JS&amp;#039;&amp;#039;&amp;#039; in touch with &amp;#039;&amp;#039;&amp;#039;Jacinta Yap&amp;#039;&amp;#039;&amp;#039;.&lt;/div&gt;</summary>