Proton Calorimetry/Meetings/2017/03/29: Difference between revisions
| SimonJolly (talk | contribs) No edit summary | SimonJolly (talk | contribs)  No edit summary | ||
| (One intermediate revision by the same user not shown) | |||
| Line 6: | Line 6: | ||
| '''ABF''': | '''ABF''': | ||
| *   | * Looking at specific peak PMT current: | ||
| ** Acquire data with different rates: | |||
| ** Calculate average current to compare at what point saturation occurs. | |||
| ** Matches predictions almost exactly! | |||
| ** Small rise at "saturation" current before drop off. | |||
| * Will pass on information to Hamamatsu to "guide" them in producing lower gain PMTs. | |||
| '''LK''': | '''LK''': | ||
| * [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2017/LK20170329_ProtonBuildUp.pdf Looking at dose build-up effect in proton therapy and secondary particles]. | * [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2017/LK20170329_ProtonBuildUp.pdf Looking at dose build-up effect in proton therapy and secondary particles]. | ||
| **  | ** Secondary particles in Geant4 difficult to characterise due to range cut. | ||
| **  | ** <code>GetTotalEnergyDeposit()</code> doesn't include energy from secondary particles... | ||
| *  | ** Need to check whether 20 micron range cut is short enough with '''Adam Gibson'''. | ||
| *  | * Clear build-up effect from secondary protons: | ||
| *  | ** Need to check RBE of the resulting short-range protons. | ||
| ** Effect of hadronic build-up means Bragg curve incorrect for entrance dose. | |||
Latest revision as of 14:11, 29 March 2017
Minutes for UCL Proton Calorimetry Meeting, 29th March 2017 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Laurent Kelleter, Anastasia Basharina-Freshville
ABF:
- Looking at specific peak PMT current:
- Acquire data with different rates:
- Calculate average current to compare at what point saturation occurs.
- Matches predictions almost exactly!
- Small rise at "saturation" current before drop off.
 
- Will pass on information to Hamamatsu to "guide" them in producing lower gain PMTs.
LK:
- Looking at dose build-up effect in proton therapy and secondary particles.
- Secondary particles in Geant4 difficult to characterise due to range cut.
- GetTotalEnergyDeposit()doesn't include energy from secondary particles...
- Need to check whether 20 micron range cut is short enough with Adam Gibson.
 
- Clear build-up effect from secondary protons:
- Need to check RBE of the resulting short-range protons.