(Created page with "== Minutes for UCL Proton Beam Therapy Group Meetings, 1st April == === Present === '''Joe Bateman''', '''Sonia Escribano''', '''Matt Warren''', '''Harry Barnett''', '''Simon Jolly''' === Matt Warren === * String of 8 DDC boards seems to work but only if integration is greater than 600 otherwise overlaps - so need to find ways to make faster === Simon Jolly === * Nuvia invited us out to Prague on w/b 7/4 or 21/4 * Spoke to Czech PTC pro...") |
|||
Line 11: | Line 11: | ||
=== [[ELogs/SimonJolly|Simon Jolly]] === | === [[ELogs/SimonJolly|Simon Jolly]] === | ||
* | * Prague PTC planned measurements | ||
** Shoot through calibrations | |||
* | ** Pristine Bragg peaks | ||
** SOBP treatment plan | |||
* | ** WET measurement at same time as shoot through calibrations | ||
** Pristine Bragg peaks | ** Moving couch to ensure perfectly straight beams at different lateral positions | ||
** | ** 30,000 measurements ~ 5 secs for pristine Bragg peaks | ||
** Moving | |||
** | |||
Latest revision as of 09:45, 29 April 2025
Minutes for UCL Proton Beam Therapy Group Meetings, 1st April
Present
Joe Bateman, Sonia Escribano, Matt Warren, Harry Barnett, Simon Jolly
Matt Warren
- String of 8 DDC boards seems to work but only if integration is greater than 600 otherwise overlaps - so need to find ways to make faster
Simon Jolly
- Prague PTC planned measurements
- Shoot through calibrations
- Pristine Bragg peaks
- SOBP treatment plan
- WET measurement at same time as shoot through calibrations
- Moving couch to ensure perfectly straight beams at different lateral positions
- 30,000 measurements ~ 5 secs for pristine Bragg peaks
Sonia Escribano
- To-do list prepared for Prague
- Fake-generated data to check “live acquisition” calibration and firing
- For long runs not possible to kill acquisition from GUI (I.e. stop button stops calibration and fitting) - need to access to ftdi from GUI which is blocked by web servers
- On patch panel of Peli case in case pi’s don’t work and need to use DAQ laptop