Quality Assurance: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
Line 14: Line 14:


====[https://www.iba-dosimetry.com/product/lynx-pt Lynx/Sphinx]====
====[https://www.iba-dosimetry.com/product/lynx-pt Lynx/Sphinx]====
** Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
* Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
** For performing spot size and position measurements and numerous energies.
* For performing spot size and position measurements and numerous energies.
** 0.4 mm thick and 300 x 300 mm^2 Ga- based plastic scintillator screen, with mirror and CCD camera.  
* 0.4 mm thick and 300 x 300 mm^2 Ga- based plastic scintillator screen, with mirror and CCD camera.  
**Technical specs:
*Technical specs:
*** Pixel size: 4.65 x 4.65 um²
** Pixel size: 4.65 x 4.65 um²
*** Effective spacial resolution: 0.5 mm
** Effective spacial resolution: 0.5 mm
*** Video camera: 1024 x 1024, 12-bit resolution
** Video camera: 1024 x 1024, 12-bit resolution
*** Sampling time: 7 images / s
** Sampling time: 7 images / s
*** Dynamic range can be modified through CCD camera gain settings and lens aperture.
** Dynamic range can be modified through CCD camera gain settings and lens aperture.
*** Total dimensions 360 x 370 x 600 mm
** Total dimensions 360 x 370 x 600 mm
** Sphinx phantom consists of wedges for range consistency checks for 4 energies (no direct range measurement) and absolute dose measurements with [https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber].
* Sphinx phantom consists of wedges for range consistency checks for 4 energies (no direct range measurement) and absolute dose measurements with [https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber].
** Used with myQA machine software: myQA Machines Software
* Used with myQA machine software: myQA Machines Software




* [https://www.iba-dosimetry.com/product/sphinx-compact Sphinx Compact]
====[https://www.iba-dosimetry.com/product/sphinx-compact Sphinx Compact]====
** Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
* Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
** Similar to Lynx detector and Sphinx phantom, but is instead an Silicon flat-panel detector.
* Similar to Lynx detector and Sphinx phantom, but is instead an Silicon flat-panel detector.
** Advertised as being able to complete daily QA measurements in <10 mins.
* Advertised as being able to complete daily QA measurements in <10 mins.
** Technical specs:
* Technical specs:
*** 200 x 200 mm^2 flat-panel detector.
** 200 x 200 mm^2 flat-panel detector.
*** 0.2 mm spatial resolution
** 0.2 mm spatial resolution
*** 16 bit depth
** 16 bit depth
*** Six different gain values are available: 0.25, 0.5, 1, 2, 4, and 8 pF
** Six different gain values are available: 0.25, 0.5, 1, 2, 4, and 8 pF
** Interval time can be adjusted in 4 steps (100, 200, 400, and 800 ms) - equivalent to dose rates of 0.4 - 4000 Gy/min
* Interval time can be adjusted in 4 steps (100, 200, 400, and 800 ms) - equivalent to dose rates of 0.4 - 4000 Gy/min
*** Approx 11 kg weight.
** Approx 11 kg weight.
** Phantom consists of wedges for range consistency checks for 3 energies (no direct range measurement) and absolute dose measurements with [https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber].
* Phantom consists of wedges for range consistency checks for 3 energies (no direct range measurement) and absolute dose measurements with [https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber].
** Used with myQA machine software: myQA Machines Software
* Used with myQA machine software: myQA Machines Software
** https://www.iba-dosimetry.com/fileadmin/user_upload/products/03_proton_therapy/Sphinx_Compact/J_Applied_Clin_Med_Phys_-_2019_-_Rana_-_Development_and_long%E2%80%90term_stability_of_a_comprehensive_daily_QA_program_for_a__1_.pdf
* https://www.iba-dosimetry.com/fileadmin/user_upload/products/03_proton_therapy/Sphinx_Compact/J_Applied_Clin_Med_Phys_-_2019_-_Rana_-_Development_and_long%E2%80%90term_stability_of_a_comprehensive_daily_QA_program_for_a__1_.pdf




* [https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber]
====[https://www.iba-dosimetry.com/product/ppc05-plane-parallel-chamber PPC05 Plane Parallel Chamber]====
** Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
* Usage: Daily QA, Monthly QA, Annual QA, Commissioning  
** 0.6 mm plate spacing, 9.9 mm diameter, and a 3.4 mm guard ring
* 0.6 mm plate spacing, 9.9 mm diameter, and a 3.4 mm guard ring
** Used with reference class electrometer [https://www.iba-dosimetry.com/product/dose-x Dose-X]  
* Used with reference class electrometer [https://www.iba-dosimetry.com/product/dose-x Dose-X]  
** Multiple use cases:
* Multiple use cases:
*** Daily QA - used with Lynx/Sphinx or Sphinx Compact inside phantom wedges for machine output verification.
** Daily QA - used with Lynx/Sphinx or Sphinx Compact inside phantom wedges for machine output verification.
*** Within standard solid water phantom for dose output verification.
** Within standard solid water phantom for dose output verification.
*** Used within Blue Phantom PT (https://www.iba-dosimetry.com/product/blue-phantom-pt) for absolute dose measurements and depth dose profiles in a water phantom.
** Used within Blue Phantom PT (https://www.iba-dosimetry.com/product/blue-phantom-pt) for absolute dose measurements and depth dose profiles in a water phantom.




====[https://www.iba-dosimetry.com/product/myqa-phoenix myQA Phoenix]====
* Usage: Monthly QA, Annual QA, Commissioning
* High-resolution amorphous silicon digital detector array.
* Capable of single shot and movie mode measurements.
* Technical specs:
** 2048 × 2048 (4,194,304) pixels.
** 0.2mm resolution.
** 1 frame/sec with 65536 counts/frame sampling frequency.
** 582 × 522 × 31 mm³
** 13 kg
** Fast ethernet communication
* Comes with foot stand & alignment bar for quick setup.


* [https://www.iba-dosimetry.com/product/myqa-phoenix myQA Phoenix]
** Usage: Monthly QA, Annual QA, Commissioning
** High-resolution amorphous silicon digital detector array.
** Capable of single shot and movie mode measurements.
** Technical specs:
*** 2048 × 2048 (4,194,304) pixels.
*** 0.2mm resolution.
*** 1 frame/sec with 65536 counts/frame sampling frequency.
*** 582 × 522 × 31 mm³
*** 13 kg
*** Fast ethernet communication
** Comes with foot stand & alignment bar for quick setup.


 
====[https://www.iba-dosimetry.com/product/myqa-matrixx-air myQA MatriXX AiR]====
 
* Usage: PSQA
* [https://www.iba-dosimetry.com/product/myqa-matrixx-air myQA MatriXX AiR]
* Wireless ionisation chamber array used for planar verification of of patient treatment plans.  
** Usage: PSQA
* WiFi and battery operation mode available.
** Wireless ionisation chamber array used for planar verification of of patient treatment plans.  
* Technical specs:
** WiFi and battery operation mode available.
** 1521 air-vented ICs
** Technical specs:
** 25 × 25 cm² area
*** 1521 air-vented ICs
** 6.5 mm center-to-center resolution
*** 25 × 25 cm² area
** Minimum sampling time of 20 ms
*** 6.5 mm center-to-center resolution
** Detector dimensions: 57.6x32x4cm
*** Minimum sampling time of 20 ms
** 7.3kg weight (inc battery)
*** Detector dimensions: 57.6x32x4cm
* Reads out 2D dose distribution at different depths and gantry angles using miniPhantom R & Gantry Sensor+.
*** 7.3kg weight (inc battery)
* Compatible with protons and carbon ions.
** Reads out 2D dose distribution at different depths and gantry angles using miniPhantom R & Gantry Sensor+.
* conformalFLASH ready
** Compatible with protons and carbon ions.
* Compatible with DynamicArc (proton arc therapy) using gantry angle sensor and rotating holder.  
** conformalFLASH ready
** Compatible with DynamicArc (proton arc therapy) using gantry angle sensor and rotating holder.  





Revision as of 19:59, 20 August 2026

A reading list for QA devices

Articles on Detectors

  • "Dosimetry for ion beam therapy" (2010)

This paper looks at current methods and standards for PBT dosimetry. It also gives advantages and disadvantages of each method. This paper was particularly useful for looking at film dosimetry and ionization chambers. https://iopscience.iop.org/article/10.1088/0031-9155/55/21/R01/meta

  • "A critical review of the practices of proton daily quality assurance programs" (2021)

https://dx.doi.org/10.21037/TRO-21-11

List of Commercially Available Devices

IBA Dosimetry

Lynx/Sphinx

  • Usage: Daily QA, Monthly QA, Annual QA, Commissioning
  • For performing spot size and position measurements and numerous energies.
  • 0.4 mm thick and 300 x 300 mm^2 Ga- based plastic scintillator screen, with mirror and CCD camera.
  • Technical specs:
    • Pixel size: 4.65 x 4.65 um²
    • Effective spacial resolution: 0.5 mm
    • Video camera: 1024 x 1024, 12-bit resolution
    • Sampling time: 7 images / s
    • Dynamic range can be modified through CCD camera gain settings and lens aperture.
    • Total dimensions 360 x 370 x 600 mm
  • Sphinx phantom consists of wedges for range consistency checks for 4 energies (no direct range measurement) and absolute dose measurements with PPC05 Plane Parallel Chamber.
  • Used with myQA machine software: myQA Machines Software


Sphinx Compact


PPC05 Plane Parallel Chamber

  • Usage: Daily QA, Monthly QA, Annual QA, Commissioning
  • 0.6 mm plate spacing, 9.9 mm diameter, and a 3.4 mm guard ring
  • Used with reference class electrometer Dose-X
  • Multiple use cases:
    • Daily QA - used with Lynx/Sphinx or Sphinx Compact inside phantom wedges for machine output verification.
    • Within standard solid water phantom for dose output verification.
    • Used within Blue Phantom PT (https://www.iba-dosimetry.com/product/blue-phantom-pt) for absolute dose measurements and depth dose profiles in a water phantom.


myQA Phoenix

  • Usage: Monthly QA, Annual QA, Commissioning
  • High-resolution amorphous silicon digital detector array.
  • Capable of single shot and movie mode measurements.
  • Technical specs:
    • 2048 × 2048 (4,194,304) pixels.
    • 0.2mm resolution.
    • 1 frame/sec with 65536 counts/frame sampling frequency.
    • 582 × 522 × 31 mm³
    • 13 kg
    • Fast ethernet communication
  • Comes with foot stand & alignment bar for quick setup.


myQA MatriXX AiR

  • Usage: PSQA
  • Wireless ionisation chamber array used for planar verification of of patient treatment plans.
  • WiFi and battery operation mode available.
  • Technical specs:
    • 1521 air-vented ICs
    • 25 × 25 cm² area
    • 6.5 mm center-to-center resolution
    • Minimum sampling time of 20 ms
    • Detector dimensions: 57.6x32x4cm
    • 7.3kg weight (inc battery)
  • Reads out 2D dose distribution at different depths and gantry angles using miniPhantom R & Gantry Sensor+.
  • Compatible with protons and carbon ions.
  • conformalFLASH ready
  • Compatible with DynamicArc (proton arc therapy) using gantry angle sensor and rotating holder.


  • Giraffe
    • Usage: Monthly QA, Annual QA, Commissioning
    • A high resolution multi-layer ionisation chamber for single-shot Bragg Peak measurements.
  • Zebra
    • Usage: Monthly QA, Annual QA, Commissioning
  • StingRay
    • Usage: Monthly QA, Annual QA, Commissioning

PTW

Sun Nuclear

DET.TEC.TOR

Logos Systems

MedScint