Beam tests of the single module with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 36 MeV beam.

Equipment List

Item Notes
Single Module Scintillator Block Optical gel required to couple Scintillator to PMT
Photomultiplier Tube (Hamamatsu 2"?)
Portable Enclosure Modified Peli 1510 Waterproof Wheeled Equipment Case.

230 x 555 x 350mm
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables.
Requires a window (paper? Mylar? tape?) to ensure the opening for the beam is light-tight.

LeCroy HDO6104 Oscilloscope Records PMT output
DAQ Laptop Records HV output / Controls Caen HV supply
Caen NDT1470 HV Supply Supplies HV to PMT
Control Laptop x 2 One each for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop.
Network Hub x 2 One for the experimental room for the LeCroy HDO6104 and DAQ Laptop to connect to,

one for the control room for each of the Control Laptops to connect to.

Ethernet Cable x 4 To connect each control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs.
Ethernet Cable To connect the two Network Hubs and complete the network for controlling DAQ equipment from the control room.
SMA (female) to BNC (male) Cable Signal from enclosure port to LeCroy Oscilloscope
SHV Cable HV supply from experimental room to enclosure port
USB Cable Caen HV unit to DAQ Laptop