Proton Calorimetry/Experimental Runs/2018/Feb21

From PBTWiki
Jump to navigation Jump to search

Beam tests of the single module with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 36 MeV beam.

Equipment List

Item Notes
Single Module Scintillator Block Optical grease required to couple Scintillator to PMT
Photomultiplier Tube (Hamamatsu 2"?)
Portable Enclosure Modified Peli 1510 Waterproof Wheeled Equipment Case.

230 x 555 x 350mm
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables.
Requires a window (paper? Mylar? tape?) to ensure the opening for the beam is light-tight.

LeCroy HDO6104 Oscilloscope Requires a power supply.
DAQ Laptop Requires a power supply. (Connected to enclosure how? Or to LeCroy HDO6104? Requires USB?)
Control Laptop x 2 One each for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Require power supplies.
Linksys EA6900 Network Hub x 2 One for the experimental room for the LeCroy HDO6104 and DAQ Laptop to connect to,

one for the control room for each of the Control Laptops to connect to.

Ethernet Cable (Long) To connect the two Network Hubs and complete the network for controlling DAQ equipment from the control room.
BNC to SMA Cable (Short) Signal from PMT to enclosure port
SMA to BNC Cable (Long) Signal from enclosure port to LeCroy Oscilloscope
SHV Cable (Short) HV supply from enclosure port to PMT
SHV Cable (Long) HV supply from experimental room to enclosure port