Proton Calorimetry/Meetings/2016/11/02

From PBTWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Minutes for UCL Proton Calorimetry Meeting, 5th November 2016 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Ruben Saakyan, Laurent Kelleter, Andreas Christou, Matthieu Hentz, Adam Knoetze

RS:

  • Dates for next Clatterbridge run set: 24th/25th November.
  • Planning for next run:
    • Same measurements as last run but with our divider rather than Hamamatsu active divider:
      • Our divider contains no active components (transistors etc.) to linearise response of PMT: may be reason for high rate distortion.
      • Additional capacitive resistance in active divider means higher resistance for high rates.
    • Measure high rate and linearity: retake wheel measurement.
    • Record Caen ADC, Caen waveform and scope waveform.
    • Take both scintillator blocks: start with new block, try old block if we have time.
  • Check with Anastasia about potential questions for next run.

AK:

  • Converted all data from LeCroy scope format on plus1.
  • Can’t easily find peaks as all waveforms concatenated together with continuous timebase.
  • Looking at ROOT, Geant4 tutorials and detector emulator manual.
  • Will start looking at producing periodic pulses from detector emulator.
  • Aim is to produce replica of PMT output signal for proton light pulse with realistic noise variation.

MH:

  • Looking at energy deposition with proton pencil beam tutorials on PBT Wiki.
  • Comparing energy deposition in scintillator and water: seeing nice Bragg Peaks!
  • Will redo simulations using 60MeV pencil beam and check match to Clatterbridge data. Also replot with finer energy and position resolution.
  • Next step is to start integrating Clatterbridge beamline simulation and characterise the effect of adding in each component.

AC:

  • Looking at improving fitting of Caen ADC spectrum.
  • Improved quality of fit by increasing convolution number: reduces Chi2 by about half, but doubles time to produce fit.
  • Newer fit works over larger range, improving errors on fit, but results in slightly larger energy resolution.
  • Will look at other spectra before moving onto waveform data.

LK:

  • Running simulations in Geant4 of segmented calorimeter.
  • Reading out photon production for individual scintillator slices in response to single protons.
  • Seeing both Bragg Peak and effects of quenching!
  • Possible bug in Geant4: total energy deposition in scintillator + wrapping more than initial energy.
  • Will fix scintillator and wrapping thickness and add more layers for higher energy.

SJ:

  • Date of next visit to Clatterbridge fixed for 24th/25th November.
  • Have heard back from Liviu Penescu at MedAustron: still waiting on possible dates to visit for experimental runs. Liviu to confirm availability of collimators and mounting.
  • Also need to arrange PSI visit: Ros Perrin/Tony Lomax lung phantom with UCL scintillator.
  • Requested that future talks uploaded to wikiData presentations directory contain some description of the data they show and include useful info in filename.