Proton Calorimetry/Meetings/2021/07/02: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
Line 13: Line 13:
*Neither combination gives acceptable results: lots of gaps in paint layer due to either inconsistencies in sheet thickness, placement misalignment or paint reaction.
*Neither combination gives acceptable results: lots of gaps in paint layer due to either inconsistencies in sheet thickness, placement misalignment or paint reaction.
**Placement of sheets when glueing is difficult: not much room to adjust once placed as this ruins paint layer.
**Placement of sheets when glueing is difficult: not much room to adjust once placed as this ruins paint layer.
*New fitting routine using Gauss–Legendre algorithm and Fumili minimiser implemented into photodiode scripts.
**New routine gives reasonable results where default options either fail or give strange fit results.
**With a given set of fit results, Gauss–Legendre draws Bortfeld curve slightly differently compared to default Adaptive Singular algorithm.
**Might require some optimisation of numerical parameters to correct this. Will investigate, but might be that "slow, accurate, non-live" fit use slower Adaptive Singular to draw curves.
*Organised new inventory and beam test equipment into new DeWalt tower – tower kept in D109.
*Installed


=== [[ELogs/FernPannell|Fern Pannell]] ===
=== [[ELogs/FernPannell|Fern Pannell]] ===
*
*

Revision as of 10:24, 5 July 2021

Minutes for UCL Proton Calorimetry Meetings, 23rd June

Present

Simon Jolly, Saad Shaikh, Fern Pannell

Saad Shaikh

  • Painted 4 scintillator sheet pairs:
    • Sheets 48 & 23 with primer – one layer to glue pair.
    • Sheets 54 & 1 with appliance – one layer to glue pair.
    • Sheets 52 & 11 with appliance and then primer to glue pair – 10-15 mins for appliance layer to dry.
    • Sheets 53 & 2 with appliance and then primer to glue pair – 30-40 mins for appliance layer to dry.
  • Neither combination gives acceptable results: lots of gaps in paint layer due to either inconsistencies in sheet thickness, placement misalignment or paint reaction.
    • Placement of sheets when glueing is difficult: not much room to adjust once placed as this ruins paint layer.
  • New fitting routine using Gauss–Legendre algorithm and Fumili minimiser implemented into photodiode scripts.
    • New routine gives reasonable results where default options either fail or give strange fit results.
    • With a given set of fit results, Gauss–Legendre draws Bortfeld curve slightly differently compared to default Adaptive Singular algorithm.
    • Might require some optimisation of numerical parameters to correct this. Will investigate, but might be that "slow, accurate, non-live" fit use slower Adaptive Singular to draw curves.
  • Organised new inventory and beam test equipment into new DeWalt tower – tower kept in D109.
  • Installed

Fern Pannell