Proton Calorimetry/Meetings/2022/07/27: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
No edit summary
 
(One intermediate revision by the same user not shown)
Line 13: Line 13:
**Route 2 by the Association of Clinical Scientists is a useful way to gain clinical certification while working as an e.g. clinical technologist. This is something that can be done after postdoc.
**Route 2 by the Association of Clinical Scientists is a useful way to gain clinical certification while working as an e.g. clinical technologist. This is something that can be done after postdoc.
*Will meet with Colin Baker at UCLH on Tuesday to discuss similar career prospects and making a Giraffe WET measurement of Rev. B and Rev. C stacks during monthly QA measurements.
*Will meet with Colin Baker at UCLH on Tuesday to discuss similar career prospects and making a Giraffe WET measurement of Rev. B and Rev. C stacks during monthly QA measurements.
*NUVIA could potentially send another set of 3 mm sheets – this time hopefully actually 3 mm and not 3.4 mm.
*Will meet with Charles-Antoine Collins-Fekete and rest of medical imaging group on Friday post discussion with Daniel Robertson to present the QuARC and discuss possible collaboration.
*Will meet with Charles-Antoine Collins-Fekete and rest of medical imaging group on Friday post discussion with Daniel Robertson to present the QuARC and discuss possible collaboration.
*Manchester are interested in making some (FLASH) measurements with the QuARC and do PeakFinder WET measurements of the detector. Will liaise with Sam Manger after 8th August to discuss.
*Manchester are interested in making some (FLASH) measurements with the QuARC and do PeakFinder WET measurements of the detector. Will liaise with Sam Manger after 8th August to discuss.
Line 21: Line 20:
**Will ask Matt Warren to look into this, as this will likely remain an issue with Zmod version of daughter board for Rev. D.
**Will ask Matt Warren to look into this, as this will likely remain an issue with Zmod version of daughter board for Rev. D.
**Will investigate Quad SPI programming on board to enable automatic configuration on power-up.
**Will investigate Quad SPI programming on board to enable automatic configuration on power-up.
*Currently have 3 Raspberry Pi SD cards: 32 GB (SanDisk) and 64 GB (Delkin) with normal installations and 400 GB (SanDisk) with headless installation.
*Marko has returned Raspberry Pi and Nexys Video sent for testing, and also sent Rev. D boards.
*Marko has returned Raspberry Pi and Nexys Video sent for testing, and also sent Rev. D boards.
**Will set up his Pi with Argon case for use at UCL.
**Will set up his Pi with Argon case for use at UCL. Currently have 3 Raspberry Pi SD cards: 32 GB (SanDisk) and 64 GB (Delkin) with normal installations and 400 GB (SanDisk) with headless installation.
**Will test Rev. D boards.
**Will test Rev. D boards.
*Investigated range-energy dependence of UCLH data and updated [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2022/SS220622_UCLH.pptx analysis slides].
*Investigated range-energy dependence of UCLH data and updated [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2022/SS220622_UCLH.pptx analysis slides].
**Strong range-energy dependence without any WET correction. Applying an addition of 0.086mm on average fixes this issue, though we still have some systematic underestimation of the range.
**Strong range-energy dependence without any WET correction. Applying an addition of 0.086mm on average to each clear sheet fixes this issue, though we still have some systematic underestimation of the range.
**Will make a physical measurement of mylar foil thickness, to get order of magnitude physical thickness.
**Will make a physical measurement of mylar foil thickness, to get order of magnitude physical thickness.
*Made crosstalk measurements of Rev. B and Rev. C stacks using LED fibre and added results to analysis slides.
*Made crosstalk measurements of Rev. B and Rev. C stacks using LED fibre and added results to analysis slides.
**Observe 6.5 times more crosstalk in Rev. C stack due to photodiode misalignment. Average Rev. B crosstalk of 0.77%.
**Observe 6.5 times more crosstalk in Rev. C stack due to photodiode misalignment. Average Rev. B crosstalk of 0.77%.
**Will compare calibration data with crosstalk data to see if same coupling relationship is obtained.
**Will compare calibration data with crosstalk data to see if same coupling relationship is obtained.
*NUVIA could potentially send another set of 3 mm sheets – this time hopefully actually 3 mm and not 3.4 mm.

Latest revision as of 18:16, 27 July 2022

Minutes for UCL Proton Calorimetry Meetings, 27th July

Present

Saad Shaikh, Simon Jolly, Raffaella Radogna, Unik Limbu

Saad Shaikh

  • Attended PTCOG conference in Miami and was then on holiday until 13th July.
    • No meeting last 2 weeks due to Simon being in Spain.
  • Met with Andy Poynter at UCLH to discuss career options during/post post-doc:
    • Formal 50/50 position during postdoc unlikely due to excessive commitments, but shorter term placements at UCLH are possible.
    • Longer term positions are also possible, but would need to find money to justify pausing postdoc funding.
    • Route 2 by the Association of Clinical Scientists is a useful way to gain clinical certification while working as an e.g. clinical technologist. This is something that can be done after postdoc.
  • Will meet with Colin Baker at UCLH on Tuesday to discuss similar career prospects and making a Giraffe WET measurement of Rev. B and Rev. C stacks during monthly QA measurements.
  • Will meet with Charles-Antoine Collins-Fekete and rest of medical imaging group on Friday post discussion with Daniel Robertson to present the QuARC and discuss possible collaboration.
  • Manchester are interested in making some (FLASH) measurements with the QuARC and do PeakFinder WET measurements of the detector. Will liaise with Sam Manger after 8th August to discuss.
  • Spoke with Linda Mortimer at PTCOG and Clatterbridge are interested in a compact version of the QuARC for pristine Bragg peak and SOBP measurements.
    • Will work towards developing 14-sheet (2.86mm) detector with USB104 and Raspberry Pi.
  • USB104 works with Rev. B boards, however encountered a problem with DPTI interface with TX_EN sometimes going high (disabling writing) after 19 bytes are written to the chip, causing data to be disordered and appear very noisy.
    • Will ask Matt Warren to look into this, as this will likely remain an issue with Zmod version of daughter board for Rev. D.
    • Will investigate Quad SPI programming on board to enable automatic configuration on power-up.
  • Marko has returned Raspberry Pi and Nexys Video sent for testing, and also sent Rev. D boards.
    • Will set up his Pi with Argon case for use at UCL. Currently have 3 Raspberry Pi SD cards: 32 GB (SanDisk) and 64 GB (Delkin) with normal installations and 400 GB (SanDisk) with headless installation.
    • Will test Rev. D boards.
  • Investigated range-energy dependence of UCLH data and updated analysis slides.
    • Strong range-energy dependence without any WET correction. Applying an addition of 0.086mm on average to each clear sheet fixes this issue, though we still have some systematic underestimation of the range.
    • Will make a physical measurement of mylar foil thickness, to get order of magnitude physical thickness.
  • Made crosstalk measurements of Rev. B and Rev. C stacks using LED fibre and added results to analysis slides.
    • Observe 6.5 times more crosstalk in Rev. C stack due to photodiode misalignment. Average Rev. B crosstalk of 0.77%.
    • Will compare calibration data with crosstalk data to see if same coupling relationship is obtained.
  • NUVIA could potentially send another set of 3 mm sheets – this time hopefully actually 3 mm and not 3.4 mm.