BOX services enclosed | length mms | number | type | dimensions | bend radius | outside box
| 1 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | connector PCB
| 1* | cooling capillaries | 1800 | 2 | pipe | 1.6 OD | ? | 2 connectors
| 2 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 2* | cooling sensor S1 S3 S6 | 1000 | 12 wires | TP | 200um | - | connectors
| 3 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 3* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors 2 x 12way x 9m alig. ribbon reel 4 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 4* | 5 air temp sensor | 1 humidity sensor 1000 | 10 wires | 2 wires TP | 200um | - | connectors
| 5 | LMT Harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 5* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f. tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors. 6 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 6* | cooling sensor S2 | 1000 | 4 wires | TP | 200um | - | connector
| 7 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 7* | cooling sensor S5 | 1000 | 4 wires | TP | 200um | - | connector
| 8 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 8* | - | - | - | - | - | - | -
| 9 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 9* | cooling capillaries | 1800 | 2 | pipe | 1.6 OD | ? | 2 connectors
| 10 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 10* | cooling sensor S1 S3 S6 | 1000 | 12 wires | TP | 200um | - | connectors
| 11 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 11* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors 12 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 12* | 5 air temp sensor | 1000 | 10 wires | TP | 200um | - | connectors
| 13 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 13* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors. 2 x 12 way x 9m alig. ribbon reel 14 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 14* | cooling sensor S2 | 1000 | 4 wires | TP | 200um | - | connector
| 15 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 15* | cooling sensor S5 | 1000 | 4 wires | TP | 200um | - | connector
| 16 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 16* | - | - | - | - | - | - | -
| 17 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 17* | cooling capillaries | 1800 | 2 | pipe | 1.6 OD | ? | 2 connectors
| 18 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 18* | cooling sensor S1 S3 S6 | 1000 | 12 wires | TP | 200um | - | connectors
| 19 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 19* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors. 2 x 12way x 9m alig. ribbon reel 20 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 20* | 5 air temp sensor | 1 humidity sensor 1000 | 10 wires | 2 wires TP | 200um | - | connectors
| 21 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 21* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors 22 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 22* | cooling sensor S2 | 1000 | 4 wires | TP | 200um | - | connector
| 23 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 23* | cooling sensor S5 | 1000 | 4 wires | TP | 200um | - | connector
| 24 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 24* | - | - | - | - | - | - | -
| 25 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 25* | cooling capillaries | 1800 | 2 | pipe | 1.6 OD | ? | 2 connectors
| 26 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 26* | cooling sensor S1 S3 S6 | 1000 | 12 wires | TP | 200um | - | connectors
| 27 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 27* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors 28 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 28* | 5 air temp sensor | 1000 | 10 wires | TP | 200um | - | connectors
| 29 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 29* | readout fibres | 230 | 45 830// 830// 18 x 4 | 2 4 4 f.tube | splice protect 12 way ribbon 6 way ribbon 900um | 2.3 x 4.5 3.0 x 0.3 1.5 x 0.3 20mm | - 20mm 20mm 8 x MT12 | connectors. 2 x 12way x 9m alig. ribbon reel 30 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 30* | cooling sensor S2 | 1000 | 4 wires | TP | 200um | - | connector
| 31 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| 31* | cooling sensor S5 | 1000 | 4 wires | TP | 200um | - | connector
| 32 | LMT harness | 1270 | 1 | Kapton/Al | 21 x 1.7 | 10mm | PCB
| |
---|
The sensor info is taken from the document ATL-IS-ES-0011 (DCS system) by Richard Brenner.