(Created page with "== Minutes for UCL Proton Beam Therapy Group Meetings, 12th August == === Present === '''Joe Bateman''', '''Sonia Escribano''', '''Simon Jolly''' === Joe Bateman === * Geant4 QuARC simulation of 150 MeV beam with positions between -2 and +2cm to emulate UCLH spot translation measurements * Scored both no. of photons out of each side as well as smaller scoring area to match PD size - however with 1 million histories the latter doesn't have enough...")
 
(No difference)

Latest revision as of 09:10, 6 October 2025

Minutes for UCL Proton Beam Therapy Group Meetings, 12th August

Present

Joe Bateman, Sonia Escribano, Simon Jolly

Joe Bateman

  • Geant4 QuARC simulation of 150 MeV beam with positions between -2 and +2cm to emulate UCLH spot translation measurements
  • Scored both no. of photons out of each side as well as smaller scoring area to match PD size - however with 1 million histories the latter doesn't have enough stats
  • From Heidelberg SciFi docs need to:
    • Work out what the control signals are
    • Total number of io signals from adc from max10 and how many are unique to each board and how many are shared i.e. d_out
    • Do the same with the digital pd’s Simon thinks 11 signals and 3 are shared
    • 8 signals and 5 are differential pairs on usb c