To Do
MC Simulations
Dose Reconstruction
- Reconstructing UCLH 04-5/2024 QuADProBe Beam Test Dose Distributions - mainly SOBP and 3x3x7 cm^3 box field using TOPAS (via CVMFS on HEP Cluster) and FRED (locally for now, but eventually over Hypatia GPU cluster).
 - Disagreement between depth dose curve for FRED and TOPAS (using default physics settings) - agreement in plateau but FRED has sharper and higher Bragg Peak
- Only an issue when there's an energy spread in the pencil beam (i.e. PDD's agree almost perfectly for a mono energetic beam with no spread) - likely to do with energy straggling?
 
 - Investigating physics lists and in touch with Maestro o attempt to solve discrepancy (currently taking TOPAS as ground truth)
 
QuARC & QuADProBe Geant4 Simulations
- Get Saads QuARC G4 simulation working
 - Look at QuADProBe simulation from Raffy.
 
Fibres
- Consider potential ways of calibrating fibre to PD coupling.
- Using Geant4 sim?
 - Scanning diode or uniform light source?
 
 - Hassle Simon about Hamamatsu PD arrays !!!
 - Prepare slides about DAQ systems for existing fibre / fibre array detectors
 
Conference Abstracts
- PPRIG - submitted
 
Papers
- Submit QuADProBe PSQA paper for Frontiers in Oncology special edition: Technology Developments in Proton Therapy by end of July
 
Completed
MC Simulations
Dose Reconstruction
- TOPAS Simulations fully working on cluster and used to reconstruct 3D dose distributions from QuADProBe UCLH Beam Test 2024 for frontiers paper.
 - FRED-MC working on old MacBook Air (2020) intel processor and matches TOPAS simulations. Doesn't run on new MacBook Pro as not compatible with apple silicon.
 
QuARC & QuADProBe Geant4 Simulations
- Saads QuARC G4 simulation working and added scoring onto left and right sides
 
Fibres
- Had two meetings with Blake Leverington and Julian Horne from Heidelberg on replicating/adapting the design of the frontend readout system of their fibre array monitor.
 - Have so far received assembly drawings, technical description booklet, schematics and slides.
 - Hamamatsu making S17285-128G digital readout photodiode arrays with samples expected to be ready in September 2025.
 
Conference Abstracts
Conference Talks
- Talk given at PPRIG 03/05
 
Papers
- First draft of QuADProBe PSQA paper for Frontiers in Oncology special edition: Technology Developments in Proton Therapy completed