Simon Jolly, Ruben Saakyan, Matthieu Hentz, Jordan Silverman, Dan Walker
DW:
- Making progress with extracting data from Leroy binary files:
- Aim is to load LeCroy waveform files, identify pile-up, calculate ADC counts and do it quickly.
 - Previously used χ2 for selecting bad pulses; Schmitt trigger on rising edge faster.
 - Integrating whole pulse gives broader peak with larger mean than Caen.
 - Shortening integration window makes LeCroy peak match with Caen, even for low counts.
 
 - To Do:
- Update information on Wiki.
 - Badger Tony Price for tracker files!!.
 - Work out how to calculate incoming trigger rate for LeCroy scope.
 
 
JS:
- Reanalysed scintillator sheet thicknesses:
- 3 mm sheets are closer to 2.75 mm but variation is mostly below 100 microns.
 - 2 mm sheets have 2 groupings:
 - 2.0 mm group has better flatness than 2.6 mm group.
 - Thickness sigma of 3 mm sheets 90% below 30 micron target.
 
 - Continuing to work on Clatterbridge simulations:
- Needs a list of things to do!
 
 - To Do:
- Write up scintillator sheet measurements and post iPython notebook with analysis.
 - MH will but JS in touch with Jactina Yap to include more components in beamline.
 
 
MH:
- Update from Jacinta Yap on Clatterbridge:
- Spoken to Andrzej Kacperek about positions of cap and nozzle: positions and locations shouldn't make difference to treatment.
 - Dose monitor foils are 20 microns with air gap in between of 2 mm.
 - Jacinta needs to know input parameters, particularly energy and energy spread.
 
 - Trying to replicate bug in buffered readout for Geant4.
 - Currently compiling Geant4 on Virtual Machine on new MacBook.
 - To Do:
- Buffering of readout in Geant4.
 - Put JS in touch with Jacinta Yap.